Stembanc Inc
100 7th Ave Ste 200, Chardon, Ohio, United States
FEI 3004195871
FDA has 6 inspections on file for Stembanc Inc in Chardon, Ohio (FEI 3004195871), from 2009 to 2024. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Six regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 6, 2009–2024
- 0 OAI · 4 VAI · 2 NAI
- Inspections with 483 observations shown
- 4 of 6
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Validation & approval--established procedures
Processes with results which could not be fully verified by inspection and tests, were not validated and approved according to established procedures.
Quality audits performed periodically
Periodic quality audits of activities related to core CGTP requirements have not been performed.
Procedures and release criteria
Procedures including release criteria for activities relating to the distribution of HCT/Ps were not revised.
Causing contamination, increasing risks
HCT/Ps were not processed in a way that does not cause contamination or cross contamination during processing and that does not increase the risk of introduction, transmission, or spread of communicable disease.
Deviations--evaluation, cause, corrective action
Investigation of deviations related to core CGTP requirements did not include efforts to determine the cause of the deviation and corrective action(s) to address the deviation and prevent recurrence.
Show 1 more citation
Birth mother sample not tested
A sample from the birth mother of a donor one month of age or younger was not used for testing of communicable disease agents.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Autologous use only--labeling
HCT/Ps for autologous use and for which the donor eligibility determination was not performed were not labeled for autologous use only.
Eligibility not required--warning labels
HCT/Ps for which the donor eligibility determination was not performed were not prominently labeled with the appropriate warning statements.
Listing and interpretation of CD tests performed
The summary of records for HCT/Ps did not contain of all communicable disease tests performed.
Birth mother sample not tested
A sample from the birth mother of a donor one month of age or younger was not used for testing of communicable disease agents.
All labeling requirements met
Labeling procedures did not ensure that HCT/Ps are labeled in accordance with all labeling requirements.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Manufacturer instructions not followed
Testing for communicable disease agents was not performed in accordance with the manufacturer's instructions.
Improper release prevention--storage, I.D.
HCT/Ps from ineligible donors are not stored and identified in a manner to prevent improper release.
Training of personnel
The quality program has not ensured the proper training and education of personnel involved in core GTP activities.
Risk factors, clinical evidence
Donors were not screened by a review of relevant medical records for clinical evidence of communicable disease agents and diseases.
Plasma diluted test specimens
Donors were not determined to be ineligible whose communicable disease test specimens were plasma diluted, and an appropriate algorithm was not used to determine that the plasma dilution did not affect the test results.
Show 4 more citations
Deviations--evaluation, cause, corrective action
Investigation of deviations related to core CGTP requirements did not include efforts to determine the cause of the deviation and corrective action(s) to address the deviation and prevent recurrence.
Availability of procedures
Procedures for core CTGP requirements were not available to personnel in the area where operations are performed, or in a nearby area when such availability is impractical.
Completion of eligibility determination
HCT/Ps were not kept in quarantine until completion of the donor-eligibility determination.
Ensurane of compliance
You did not ensure that establishment(s) that by contract, agreement or arrangement, perform manufacturing steps for you were in compliance with applicable CGTP requirements after information became available that suggested the establishment was no longer in compliance.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Process validation procedures
Procedures to validate and approve processes that cannot be fully verified by inspection and tests were not followed.
Birth mother sample not tested
A sample from the birth mother of a donor one month of age or younger was not used for testing of communicable disease agents.
Ensurane of compliance
You did not ensure that establishment(s) that by contract, agreement or arrangement, perform manufacturing steps for you were in compliance with applicable CGTP requirements prior to the initiation of the contract, agreement of arrangement and applicable CGTP requirements after information became available that suggested the establishment was no longer in compliance.
Documentation elements for activities
Documentation for activities related to the receipt of HCT/Ps did not include identification of the HCT/P and the establishment that supplied the HCT/P and activities performed and the results of each activity.
Records incomplete
Records did not identify the person performing the work and were not detailed as necessary to provide a complete history of work performed.
Show 5 more citations
Determination based on screening and testing
HCT/P donors were not determined to be eligible based on the results of donor screening and testing.
Responsible person to determine, document
The eligibility of an HCT/P donor was not determined and documented by a responsible person, based on results of donor screening and donor testing.
Improper release prevention--storage, I.D.
HCT/Ps from ineligible donors are not stored in a manner to prevent improper release.
Procedures for all other requirements
Procedures for all steps performed in the testing and screening of donor eligibility of HCT/Ps were not established and followed.
Aseptic processing---cleaning, disinfecting
Environmental controls do not provide for adequate disinfecting of equipment to ensure aseptic processing.
Regulations FDA cited here
The 17 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 1271.80What are the general requirements for donor testing?4 of 4
- 21 CFR 1271.65How do I store an HCT/P from a donor determined to be ineligible, and what uses of the HCT/P are not prohibited?2 of 4
- 21 CFR 1271.150Current good tissue practice requirements2 of 4
- 21 CFR 1271.160Establishment and maintenance of a quality program2 of 4
- 21 CFR 1271.230Process validation2 of 4
- 21 CFR 1271.265Receipt, predistribution shipment, and distribution of an HCT/P2 of 4
- 21 CFR 1271.47What procedures must I establish and maintain?1 of 4
- 21 CFR 1271.50How do I determine whether a donor is eligible?1 of 4
Show all 17
- 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?1 of 4
- 21 CFR 1271.60What quarantine and other requirements apply before the donor-eligibility determination is complete?1 of 4
- 21 CFR 1271.75How do I screen a donor?1 of 4
- 21 CFR 1271.90Are there other exceptions and what labeling requirements apply?1 of 4
- 21 CFR 1271.180Procedures1 of 4
- 21 CFR 1271.195Environmental control and monitoring1 of 4
- 21 CFR 1271.220Processing and process controls1 of 4
- 21 CFR 1271.250Labeling controls1 of 4
- 21 CFR 1271.270Records1 of 4
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004195871 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004195871. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.