FDA has 7 inspections on file for Delta Pharma Inc in Ripley, MS (FEI 3004034796), from 2010 to 2025. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Feb 23, 2017. FDA issued a warning letter on (CDER). FDA's compliance record also lists one other action under this FEI: Injunction, . No import refusal is filed under this FEI.

Six regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
7, 2010–2025
4 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
6 of 7
4 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
7 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetClassification not posted yetoutsourcing facilityPosted 483 · 2 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Missing required labeling statements

      OBSERVATION 1 The labels of your outsourcing facility's drug products do not include information required by 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act. Specifically, the semaglutide finished product 05-0525-001, 05-0525-002, and 05-0525-003 do not include the form, and the statements "NOT FOR RESALE" and "OFFICE USE ONLY". Material System

    2. Observation 2

      Components not retested after storage

      OBSERVATION 2 Approved components are not retested or reexamined for purity after storage for long periods with subsequent approval or rejection by the quality control unit. Specifically, the raw material, Sterile water for Injection, USP, lot (6) 02], expiration date 31 March 2025, was used in the production batch 02-0225-001, expiration date 02 April 2025. The lot produced [illegible] vials which were distributed for commercial use.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 citation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Clothing appropriate for duties performed

      Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.

    3. Aseptic Processing Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.

    4. Calibration/Inspection/Checking not done

      Routine calibration of equipment is not performed according to a written program designed to assure proper performance.

    5. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  6. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  7. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Sterilization/depyrogenation validation lacking

      Procedures designed to prevent microbiological contamination of drug product purporting to be sterile do not include validation of sterilization process. Specifically, a) Your firm receives non-sterile (b)(4) for use in the production of finished injectable drug products. However, you have not validated your process for sterilizing the [{_t) _{4_}]. Additionally, it is a practice of your firm to (b)(4) ... (t>) (4) ~ of finished injectable drug products. However, you have not validated your process for cleaning and sterilizing the Ko)(4) b) Your firm receives non-sterile wipes, sponges, and mop heads used for cleaning the ISO 5, ISO 7, and ISO 8 classified areas. You have not validated your process for sterilizing wipes, sponges, and mop heads. Additionally, you have not validated your process for cleaning and sterilizing the reused wipes, sponges, and mop heads. c) Media fills have not been performed by all operators who perform aseptic operations. Additionally, media fill procedures do not simulate actual processing, including but not limited to the largest batch size, and all process manipulations. d) Your firm uses an [(D) (4)] for sterilization of l•H•> used in the production of injectable drug products. However sterilization [(t>} (4)] have not been validated. e) Your firm uses an [(l:)r<4r] to depyrogenate [(l:)L(4)] sodium chloride (NaCl), however this process has not been validated. f) Post production (tl) (4) performed by your firm have repeatedly failed to meet the (b)(4) manufacturer's specifications for (Ktl) (4). No investigations were performed and the batches were released for distribution. The following batches all had recorded (!?)(4) below the specification (list is not all inclusive): - Benadram lot 04-11/23/16 - Bromphed lot 09-10/20/16 - Prometh lot 07-11/08/16 - BetasoneSA-6 lot 11-06/23/16 - Delta MP-100 lot 24-11/30/16 - Dexamethasone Acetate Suspension lot 02-08/31/16 - Dexamethasone Acetate Suspension lot 02-08/04/16 - Deltalone lot 08-08/23/16 g) (tl) (4) are not performed for (5)(4) nitrogen gas used in aseptic processing. *This is a repeat observation from FDA inspections ending on 05/24/2016 and 10/02/2013*.

    2. Observation 2

      Containers/closures not properly depyrogenated

      Drug product containers and closures were not clean, sterilized, and processed to remove pyrogenic properties to assure that they are suitable for their intended use. Specifically, depyrogenation (15)(4) (tl) (4) have not been validated. Your firm uses this ~ to depyrogenate finished product containers (amber glass vials) and glassware used in the production of finished injectable products. Also, your firm uses household dish soap to clean glassware but this cleaning process has not been validated.

    Show observations 3 to 12
    1. Observation 3

      Inappropriate personnel clothing (powdered gloves)

      Clothing of personnel engaged in the processing of injectable drug products is not appropriate for the duties they perform. Specifically, your firm uses powdered sterile gloves during the production of injectable drug products. ***This is a repeat observation from FDA inspections ending on 05/24/2016 and 10/02/2013***

    2. Observation 4

      Environmental monitoring system deficient

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a) Personnel monitoring is not performed for each production of injectable drug product. There are no recorded logs of glove tip monitoring [(~l:(4)] , logs periodically mention [(~I(4)] , however logs do not specify (1:5)(4) or which operator the sample is from. Furthermore, the logs do not specify the date environmental sample was read, the incubation temperature of the sample, or the person recording the information. No environmental monitoring has been recorded since 11/23/2016. However your firm produced (b)(4) of sterile product since 11/23/2016. b) Your firm does not perform active viable air monitoring during production of sterile drug products. c) Your firm has not established microbial limits for environmental monitoring in your ISO 5 laminar flow hood, buffer room, or ante room. ***This is a repeat observation from FDA inspections ending on 05/24/2016 and 10/02/2013***

    3. Observation 5

      Cleaning/disinfection procedures inadequate

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, cleaning and disinfection procedures are inadequate for aseptic process areas. Pre-production cleaning/disinfection of the ISO 5, ISO 7, and ISO 8 areas were observed on 02/13/2017. During this cleaning operation we observed that the operators failed to clean the kick plate (section of flooring that rises up the wall approximately 6 inches) in the ISO 7 and ISO 8 areas. One operator failed to clean the wheels on the LAFH and prep table in the ISO 7 area. Additionally, during cleaning of the return vent in the ISO 7 area the operator dropped a wipe on the floor and then picked it up and continued to use it. The floor had not yet been cleaned/disinfected. Also, a stool located in the ISO 7 area was observed to leak brown colored fluid onto the floor after cleaning it with sporicide.

    4. Observation 6

      Walls/floor not smooth or cleanable

      Aseptic processing areas are deficient in that walls are not smooth and/or hard surfaces that are easily cleanable. Specifically, chips and scratches were observed on the east and west walls of the clean room (ISO?). Approximately 7 chips and scratches were found during visual inspection of the clean room on 02/14/2017. Additionally, approximately 3 brown colored stains were observed on the clean room floor (ISO?) on 02/14/2017. ***This is a repeat observation from FDA inspection ending on 05/24/2016***

    5. Observation 7

      Failure to investigate batch discrepancies

      There is a failure to thoroughly review unexplained discrepancies and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Dexamethasone Acetate Suspension, USP lot 02-07/12/16 failed to meet specifications for potency/purity. Lot 02-07/12/16 was discarded; however your firm's quality unit did not conduct an investigation in response to this failure and your firm lacks written procedures for discrepancy investigations.

    6. Observation 8

      Equipment calibration records missing

      Routine calibration of equipment is not performed according to a written program designed to assure proper performance. Specifically, there are no records which demonstrate the following equipment has been calibrated: 1) The (15)(4) used for (15)(4). 2) Pressure gauges used to monitor pressure differentials in the ISO 7 and ISO 8 areas 3) (15)(4) thermometers used to monitor temperatures for media storage and incubation of EM samples. 4) Scales used for weighing out bulk drug ingredients and components 5) pH meter used (15)(4) *This is a repeat observation from FDA inspections ending on 05/24/2016 and 10/02/2013*.

    7. Observation 9

      No preservative efficacy testing for shelf life

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release. Specifically, your firm adds preservatives to all injectable drug products produced. However, you have not performed any testing to ensure the preservatives remain effective throughout the labeled shelf life of the product. ***This is a repeat observation from FDA inspection ending on 05/24/2016***

    8. Observation 10

      No written stability testing program

      There is no written testing program designed to assess the stability characteristics of drug products. Specifically, your firm does not have a written stability protocol and testing performed to date did not include stability indicating tests. *This is a repeat observation from FDA inspection ending on 05/24/2016*.

    9. Observation 11

      Hold times and media handling inadequate

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product. Specifically, your firm sterilizes and depyrogenates product containers, closures, and glassware used in injectable drug production. These items are stored [(l:)f(4r] or ( ~t>H 4J ] . After depyrogenation these items are held in unclassified areas until used in drug production. Hold time studies have not been performed for all storage conditions. Additionally, the (l (o) (4)) completed on (1(D) (4)) did not include growth promotion of the media used and the test media was not stored and transported to the lab under controlled storage conditions. ***This is a repeat observation from FDA inspection ending on 05/24/2016***

    10. Observation 12

      Required 'Not for resale' label missing

      The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A). Specifically, the statement, "Not for resale," is not on your drug product labels. Labels for the following drug products do not contain this statement: - Dexamethasone Acetate Suspension, USP 8 mg/ml - Betasone SA-6 6 mg/ml - Benadram 50 mg/ml - Delta MP-100 100 mg/ml - Deltalone-40 40 mg/ml - Betasone 3 mg/ml - Bromphed 10 mg/ml - Prometh 50 mg/ml ***This is a repeat observation from FDA inspection ending on 05/24/2016***

  8. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  9. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  10. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    2. Microbiological Contamination Exam

      Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.

    3. Air Supply

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

    4. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    Show 4 more citations
    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    3. Calibration/Inspection/Checking not done

      Routine calibration of equipment is not performed according to a written program designed to assure proper performance.

    4. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.

  11. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    2. Calibration/Inspection/Checking not done

      Routine calibration of equipment is not performed according to a written program designed to assure proper performance.

    3. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    4. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component.

    5. Handling and Storage to Prevent Contamination

      There was a failure to handle and store components at all times in a manner to prevent contamination.

    Show 7 more citations
    1. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    2. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    3. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    4. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    5. Storage under appropriate conditions

      Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.

    6. Buildings not maintained in good state of repair

      Buildings used in the processing of a drug product are not maintained in a good state of repair.

    7. Results not used for expiration dates, storage cond.

      Results of stability testing are not used in determining expiration dates.

Regulations FDA cited here

The 14 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 7 inspections, with how many of them cited each.

Show all 14

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • InjunctionCDER · DrugsFDA record
  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004034796 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004034796. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.