Skip to content

CRB S.A.

Route Du Verney 1, Puidoux, Switzerland

FEI 3003201474

FDA has one inspection on file for CRB S.A. in Puidoux, Switzerland (FEI 3003201474). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2013
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written procedures followed

      Procedures for the preparation of master production and control records are not described in a written procedure.

    2. Drug products-sampling procedures/specifications

      Laboratory controls do not include a determination of conformance to written descriptions of sampling procedures and appropriate specifications for drug products.

    3. Returned drug procedures in writing and followed

      Procedures describing the holding, testing, and reprocessing of returned drug products are not in writing.

    4. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    5. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing, and packing of a drug product are not maintained in a good state of repair.

    Show 7 more citations
    1. Written record not kept of program and validation data

      A written record of the program along with appropriate validation data has not been maintained in situations where backup data is eliminated by computerization or other automated processes.

    2. Air filtration system lacking in production area

      The production area air supply lacks an appropriate air filtration system.

    3. Reprocessing procedures not written or followed

      Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not written.

    4. Written program not followed

      The written stability testing program is not followed.

    5. Adequate lighting not provided

      Adequate lighting is not provided in all areas.

    6. Protective Apparel Not Worn

      Protective apparel is not worn as necessary to protect drug products from contamination.

    7. Adequate ventilation not provided

      Adequate ventilation is not provided.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 11

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3003201474, one row per refused product line.

1 refusal on 2026-07-17 · charged FRNMFGREG on 1 · no FDA sample analysis

FDA firm profile
  • 2026-07-17

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBL99

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast Imports1FX-3469266-5/20002/2

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3003201474 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3003201474. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.