Skip to content

CPC Acquisition, Inc.

397 Charles Ct Ste B, West Chicago, Illinois, United States

FEI 3002263381

FDA has one inspection on file for CPC Acquisition, Inc. in West Chicago, Illinois (FEI 3002263381). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 24 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2009
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance24 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. GMP Training Frequency

      GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.

    2. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    3. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    4. Test methods

      The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.

    5. Component written specification

      Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

    Show 19 more citations
    1. Changes to Procedures Not Reviewed, Approved

      Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit and reviewed and approved by the quality control unit.

    2. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    3. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include assignment of responsibility, description in sufficient detail of methods, equipment and materials used, and parameters relevant to the operation.

    4. Status of Each Lot Identified

      Each lot of components was not appropriately identified as to its status in terms of being quarantined, approved or rejected.

    5. Review of problem drugs

      The procedures for the annual quality standards record evaluation are deficient in that they do not address a review of complaint, recall, returned drug product, salvaged drug product, and investigation records for each drug product.

    6. Adequate lab facilities not available

      Adequate lab facilities for testing and approval or rejection of components, in-process materials, and drug products are not available to the quality control unit.

    7. No written record of investigation

      Written records are not always made of investigations into unexplained discrepancies.

    8. Control procedures fail to include the following

      Control procedures fail to include adequacy of mixing to assure uniformity and homogeneity.

    9. Written records kept in individual logs

      Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.

    10. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    11. Lab controls established, including changes

      The establishment of specifications and test procedures including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.

    12. Representative Samples

      Representative samples are not taken of each shipment of each lot of components for testing or examination.

    13. Weighing/measuring/subdividing supervision

      Component weighing operations are not adequately supervised.

    14. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    15. Component release checked by 2nd person

      Each container of component dispensed to manufacturing is not examined by a second person to assure that the component was released by the quality control unit, the weight or measure is correct as stated in the batch records, and the containers are properly identified.

    16. Calibration/Inspection/Checking not done

      Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.

    17. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    18. Review of representative number of batches

      Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    19. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.

Regulations FDA cited here

The 17 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 17

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002263381 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002263381. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.