Skip to content

Medaus, Inc.

6801 Cahaba Valley Rd Ste 116, Hoover, Alabama, United States

FEI 3001298034

FDA has 3 inspections on file for Medaus, Inc. in Hoover, Alabama (FEI 3001298034), from 2009 to 2016. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER). FDA has also posted a Form 483 dated May 5, 2016 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.

No court action or import refusal is filed under this FEI.

Five regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
3, 2009–2016
3 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Warning letters
· CDER ↗
2 on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Environmental monitoring deficiencies

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, 1) You failed to demonstrate control of your environment by exceeding action levels in the ISO 7 environment in August 2015 with 50 cfus and in February 2016 with 12 cfus of spore forming organisms and gram-positive organisms. You continue to produce sterile products without determining root cause and taking appropriate corrective action. 2) Surface and air (viable and non-viable) monitoring is not performed in the ISO 5 environment (laminar flow hood) each [illegible] sterile products are produced. Your firm only monitors the ISO 5 environment (b) (4). 3) Personnel monitoring (fingertip) is only performed [illegible]. 4) HEPA filters in the ISO 7 area have not been leak tested. 5) Pressure differentials are not monitored between the ante room non-classified area (warehouse) because there is no pressure gauge. Certification of the ISO 7 and ISO 5 environment does not occur under dynamic conditions.

    2. Observation 2

      Sterilization validation missing

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, Your media fills do not [illegible] the most challenging conditions to assure that sterile processing techniques are adequate to ensure the sterility of drug products, for example: You have not qualified, calibrated or performed [illegible] to sterilize hormone pellets. [Illegible] non-sterile materials for the products, DMSO and Testosterone Cypionate, using [illegible]. You do not always document the [illegible] of your sterilizing [process] - Documentation of this (b) (4) does not include the actual (b) (4), only the word, "pass."

    Show observations 4 to 9
    1. Observation 4

      Stability program and facility design issues

      There is no written testing program designed to assess the stability characteristics of drug products. The beyond use date of six months is assigned to all except six of your sterile products which are 30 or 90 days. Sterility and endotoxin are not included in your studies to substantiate the beyond use date to look for contamination. Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to allow cleaning, maintenance, and proper operations. a) The design of the ISO 7 room cannot assure sterile operations. There are ill HEPA filters located approximately [illegible] from the return air vents in the ceiling. These same ill HEPA filters also have large metal bookshelves located directly below them possibly causing turbulence. Your last certification indicates lower velocity and presence of microorganisms that exceed action levels in the area below/around these HEPA filters where LFHs and [illegible] are located. b) We also observed air gaps around the swinging door from the ante room (ISO 8) to ISO 7 room.

    2. Observation 5

      Inadequate batch laboratory testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, you do not conduct sterility, endotoxin and potency on all lots of sterile drug products. (b) (4) In addition, the method [illegible] used for endotoxin testing is not scientifically valid.

    3. Observation 6

      Inadequate personnel garb for aseptic ops

      Clothing of personnel engaged in the manufacture of drug products is not appropriate for the duties they perform. Specifically, employees were observed to wear non-sterile lab coats, masks, head covers and booties while producing sterile drug products. Clothing used does not cover neck or forehead of employee during aseptic operations.

    4. Observation 7

      Missing time/hold studies

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product. Specifically, you do not have any hold studies to support storing bulk held in (b) (4) prior to (b) (4).

    5. Observation 8

      Cleaning/disinfection deficiencies

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting to produce aseptic conditions. Specifically, you use non-sterile cleaning agents - and (b) (4) (b) (4) in the cleaning and sanitization of the ISO 7 room. In addition, the sterile wipes you use to clean the ISO 5 (LFH) are labeled for use in (b) (4).

    6. Observation 9

      Inadequate storage light/temperature controls

      Drug products are not stored under appropriate conditions of temperature and light so their identity, strength, quality and purity are not affected. Specifically, you do not use amber vials for any sterile drug products labeled to be protected from light.

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    2. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.

    3. Storage under appropriate conditions

      Drug products are not stored under appropriate conditions of temperature and light so that their identity, strength, quality, and purity are not affected.

    4. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

    5. Incoming lots - conformance to written specs-

      Laboratory controls do not include determination of conformance to appropriate written specifications for the acceptance of each lot within each shipment of components, drug product containers, closures, and drug products used in the manufacture, processing, packing, or holding of drug products.

    Show 7 more citations
    1. Protective Apparel Not Worn

      Protective apparel is not worn as necessary to protect drug products from contamination.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    3. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    6. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    7. Air Supply

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance17 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.

    2. Written complaint record to be maintained at facility

      A written record of each complaint is not maintained in a file designated for drug product complaints at the facility where the drug product was manufactured, processed or packed.

    3. Calibration/Inspection/Checking not done

      Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance.

    4. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    5. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    Show 12 more citations
    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written.

    2. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    3. Actual vs. theoretical yields not determined

      Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of processing of the drug product.

    4. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    5. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    6. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    7. Handling and Storage to Prevent Contamination

      There was a failure to handle and store components at all times in a manner to prevent contamination.

    8. Written Procedures to Remove Pyrogens

      There are no written standards or specifications, methods of testing, methods of cleaning, methods of sterilization, and methods of processing to remove pyrogenic properties.

    9. Accelerated stability studies

      Accelerated stability studies, combined with basic stability information, used to support tentative expiration dates are not supported with ongoing full shelf life studies.

    10. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    11. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    12. Storage under appropriate conditions

      Drug products are not stored under appropriate conditions of light so that their identity, strength, quality, and purity are not affected.

Regulations FDA cited here

The 19 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

Show all 19

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record
  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3001298034 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3001298034. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.