Skip to content

Medaus, Inc. Form 483, March 2013

FDA issued this Form 483 to Medaus, Inc. in Hoover, Alabama (FEI 3001298034) at the end of a drug inspection that ended March 22, 2013. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Mar 22, 2013
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
3,953 days after the inspection
Facility
FEI 3001298034
Hoover, Alabama

FDA's 12 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Establishment of time limitations

    Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

  2. Adequate number of batches on stability

    An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.

  3. Storage under appropriate conditions

    Drug products are not stored under appropriate conditions of temperature and light so that their identity, strength, quality, and purity are not affected.

  4. Sterility/pyrogen-free testing

    Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

  5. Incoming lots - conformance to written specs-

    Laboratory controls do not include determination of conformance to appropriate written specifications for the acceptance of each lot within each shipment of components, drug product containers, closures, and drug products used in the manufacture, processing, packing, or holding of drug products.

  6. Protective Apparel Not Worn

    Protective apparel is not worn as necessary to protect drug products from contamination.

  7. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  8. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  9. Procedures for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

  10. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

  11. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

  12. Air Supply

    Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterJan 15, 2014CDER · 299 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3001298034, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.