St. Mary's Regional Hospital

2635 N 7th St, Grand Junction, Colorado, United States

FEI 1770153

FDA has 9 inspections on file for St. Mary's Regional Hospital in Grand Junction, Colorado (FEI 1770153), from 2009 to 2024. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

The most recent OAI inspection ended on Jun 15, 2012. FDA issued a warning letter on (CBER). No court action or import refusal is filed under this FEI.

Five regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
9, 2009–2024
1 OAI · 6 VAI · 2 NAI
Inspections with 483 observations shown
3 of 9
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  2. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the collection, processing, storage and distribution of blood and blood components for allogeneic transfusion and autologous transfusion were not always established, maintained and followed.

    2. Frequency of plateletpheresis

      Failure to prevent a plateletpheresis donor from donating at a frequency greater than allowed by the applicable regulations.

    3. Accurate measurement of quantity of blood

      The standard operating procedure fails to include a written description of the blood collection procedure, including in-process precautions taken to measure accurately the quantity of blood removed from the donor.

    4. Person performing, test results, interpretation

      Records fail to identify the person performing the work and be as detailed as necessary so as to provide a complete history of the work performed.

    5. Informed consent

      Failure of the responsible physician to explain the risks and hazards of the procedure to the donor and explain the risks and hazards in a manner that the donor may give consent and had a clear opportunity to refuse.

    Show 7 more citations
    1. Following manufacturer's instructions

      Failure to use supplies and reagents in a manner consistent with instructions provided by the manufacturer.

    2. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    3. Authority lacking to review records, investigate errors

      The quality control unit lacks authority to fully investigate errors that have occurred.

    4. Provide proper equipment to meet requirements

      Failure of equipment to perform in the manner for which it was designed so as to assure compliance with the official requirements prescribed in 21 CFR 606.

    5. Suitable size, construction, etc.

      Failure to provide facilities of suitable construction so as to facilitate adequate cleaning, maintenance and proper operations.

    6. Concurrent documentation

      Records are not concurrently maintained with the performance of each significant step in the processing of each unit of blood and blood components so that all steps can be clearly traced.

    7. Required records

      Failure to maintain donor, quality control and general records.

  5. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  6. OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Blood and Blood ProductsCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Controlling storage temperatures

      The standard operating procedure fails to include a written description of the storage temperatures and methods of controlling storage temperatures for all blood products and reagents

    2. Following manufacturer's instructions

      Failure to use supplies and reagents in a manner consistent with instructions provided by the manufacturer.

    3. Quality control

      Failure to test each month (of manufacture) four units prepared from different donors at the end of the storage period for platelet count, pH of not less than 6.0 measured at the storage temperature of the unit, and actual plasma volume.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    5. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the collection, processing, storage, and distribution of blood and blood components for homologous transfusion and further manufacturing purposes are not always maintained and followed.

    Show 2 more citations
    1. Corrective action

      Failure to take immediate corrective action when the quality control testing for platelets does not meet the prescribed requirements.

    2. Thorough investigations

      Failure to perform a thorough investigation and make a record of the conclusions and follow-up of a failure of a lot or unit to meet any of its specifications.

  8. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  9. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Person performing, test results, interpretation

      Records fail to identify the person performing the work and be as detailed as necessary so as to provide a complete history of the work performed.

    2. Thorough investigations

      Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy.

    3. Documentation

      Failure to document that you have successfully notified a deferred donor and document that you have made reasonable attempts to notify a deferred donor.

    4. Prevention of contamination

      The phlebotomy site is not prepared by a method that gives maximum assurance of a sterile container of blood.

    5. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the collection and processing of blood and blood components for homologous transfusion are not always maintained and followed.

    Show 1 more citation
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 9 inspections, with how many of them cited each.

Show all 11

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCBER · BiologicsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1770153 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1770153. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.