Skip to content

21 CFR 606.40: Facilities

FDA's inspection data lists 158 Form 483 citations of 21 CFR 606.40 at 136 facilities, from January 2009 to August 5, 2026.

Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.

Form 483 citations
158
At 150 inspections
Facilities cited
136
Distinct FEIs
Most recent citation
Aug 5, 2026
Sterling Regional Medical Center
Warning letters
0
State a violation of it

The regulation

The current text of 21 CFR 606.40 from the Electronic Code of Federal Regulations.

§ 606.40 Facilities.

Facilities shall be maintained in a clean and orderly manner, and shall be of suitable size, construction and location to facilitate adequate cleaning, maintenance and proper operations. The facilities shall:

(a) Provide adequate space for the following when applicable:

(1) Private and accurate examinations of individuals to determine their eligibility as blood donors.

(2) The withdrawal of blood from donors with minimal risk of contamination, or exposure to activities and equipment unrelated to blood collection.

(3) The storage of blood or blood components pending completion of tests.

(4) The quarantine storage of blood or blood components in a designated location pending repetition of those tests that initially gave questionable serological results.

(5) The storage of finished products prior to distribution.

(6) The quarantine storage, handling and disposition of products and reagents not suitable for use.

(7) The orderly collection, processing, compatibility testing, storage and distribution of blood and blood components to prevent contamination.

(8) The adequate and proper performance of all steps in plasmapheresis, plateletpheresis and leukapheresis procedures.

(9) The orderly conduction of all packaging, labeling and other finishing operations.

(b) Provide adequate lighting, ventilation and screening of open windows and doors.

(c) Provide adequate, clean, and convenient handwashing facilities for personnel, and adequate, clean, and convenient toilet facilities for donors and personnel. Drains shall be of adequate size and, where connected directly to a sewer, shall be equipped with traps to prevent back-siphonage.

(d) Provide for safe and sanitary disposal for the following:

(1) Trash and items used during the collection, processing and compatibility testing of blood and blood components.

(2) Blood and blood components not suitable for use or distribution.

21 CFR Part 606: Current Good Manufacturing Practice for Blood and Blood Components, Subpart CRead on eCFR

Citations by year

Form 483 citations of 21 CFR 606.40 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).

Peak: 18 in 2012

Form 483 citations of 21 CFR 606.40 by inspection year
YearForm 483 citations
200915
201017
201111
201218
201313
201415
201515
201610
20176
20187
20194
20203
20214
20224
20246
20254
20266

How FDA words this citation

FDA's short descriptions and citation text on these 158 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.

Short descriptions

  • Provide space for examination72 citations
  • Clean & orderly38 citations
  • Provide adequate handwashing9 citations
  • Suitable size, construction, etc.9 citations
  • Adequate lighting, ventilation, and screening6 citations
Show 3 more
  • Provide space for quarantine of unsuitable for use items5 citations
  • Provide adequate disposal of blood & blood components4 citations
  • Provide adequate toilet facilities4 citations

Citation text

  • “Failure to provide adequate space for private examinations of individuals to determine their suitability as blood donors.”42 citations
  • “Failure to maintain facilities in a clean and orderly manner.”38 citations
  • “Failure to provide adequate space for private examinations of individuals to determine their eligibility as blood donors.”21 citations
  • “Failure to provide facilities of suitable construction so as to facilitate adequate cleaning, maintenance and proper operations.”6 citations
Show 2 more
  • “Failure to provide for safe and sanitary disposal for blood and blood components not suitable for use or distribution.”4 citations
  • “Failure to provide adequate lighting.”3 citations

Facilities cited most recently

The latest inspections where FDA cited 21 CFR 606.40, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.

Show 4 more

Often cited at the same inspection

Of the 150 inspections where FDA cited 21 CFR 606.40, the share where it also cited each of these sections.

Ask FDAgent about 21 CFR 606.40

FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
  • Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
  • A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 606.40; FDAgent quotes that sentence exactly.
  • FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.