21 CFR 640.25: General requirements
FDA's inspection data lists 49 Form 483 citations of 21 CFR 640.25 at 37 facilities, from December 2008 to May 6, 2026.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 49
- At 42 inspections
- Facilities cited
- 37
- Distinct FEIs
- Most recent citation
- May 6, 2026
- The American National Red Cross
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 640.25 from the Electronic Code of Federal Regulations.
§ 640.25 General requirements.
(a) Storage. Immediately after resuspension, Platelets shall be placed in storage at the selected temperature range. If stored at 20 to 24 °C, a continuous gentle agitation of the platelet concentrate shall be maintained throughout the storage period. Agitation is optional if stored at a temperature between 1 and 6 °C.
(b) Quality control testing. Each month four units prepared from different donors shall be tested at the end of the storage period as follows:
(1) Platelet count.
(2) pH of not less than 6.2 measured at the storage temperature of the unit.
(3) Measurement of actual plasma volume.
(4) If the results of the quality control testing indicate that the product does not meet the prescribed requirements, immediate corrective action shall be taken and a record maintained of such action.
(c) Manufacturing responsibility. All manufacturing of Platelets shall be performed at the same licensed establishment, except that the quality control testing under paragraph (b) of this section may be performed by a clinical laboratory which meets the standards of the Clinical Laboratories Improvement Amendments of 1988 (CLIA) (42 U.S.C. 263a) and is qualified to perform platelet counts. Such arrangements must be approved by the Director, Center for Biologics Evaluation and Research, Food and Drug Administration. Such testing shall not be considered as divided manufacturing, as described in § 610.63 of this chapter, provided the following conditions are met:
(1) The results of each test are received within 10 days of the preparation of the platelet concentrate, and are maintained by the establishment licensed for Platelets so that they may be reviewed by an authorized representative of the Food and Drug Administration.
(2) The licensed Platelets manufacturer has obtained a written agreement that the testing laboratory will permit an authorized representative of the Food and Drug Administration to inspect its testing procedures and facilities during reasonable business hours.
(3) The testing laboratory will participate in any proficiency testing programs undertaken by the Center for Biologics Evaluation and Research, Food and Drug Administration.
21 CFR Part 640: Additional Standards for Human Blood and Blood Products, Subpart CRead on eCFR
Citations by year
Form 483 citations of 21 CFR 640.25 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 11 in 2011
| Year | Form 483 citations |
|---|---|
| 2008 | 2 |
| 2009 | 4 |
| 2010 | 8 |
| 2011 | 11 |
| 2012 | 2 |
| 2013 | 2 |
| 2014 | 6 |
| 2015 | 3 |
| 2016 | 1 |
| 2017 | 1 |
| 2018 | 3 |
| 2019 | 1 |
| 2023 | 3 |
| 2025 | 1 |
| 2026 | 1 |
How FDA words this citation
FDA's short descriptions and citation text on these 49 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Storage temps./agitation27 citations
- Quality control14 citations
- Corrective action8 citations
Citation text
- “Failure to store platelets immediately after resuspension at 20 to 24 degrees Celsius with continuous gentle agitation.”25 citations
- “Failure to test each month (of manufacture) four units prepared from different donors at the end of the storage period for platelet count, pH of not less than 6.0 measured at the storage temperature of the unit and actual plasma volume.”10 citations
- “Failure to take immediate corrective action and maintain a record of corrective action when the quality control testing for platelets does not meet the prescribed requirements.”3 citations
- “Failure to take immediate corrective action when the quality control testing for platelets does not meet the prescribed requirements.”3 citations
Show 2 more
- “Failure to test each month (of manufacture) four units prepared from different donors at the end of the storage period for platelet count.”3 citations
- “Failure to maintain a record of corrective action when the quality control testing for platelets does not meet the prescribed requirements.”2 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 640.25, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
Show 4 more
- Presbyterian/St. Luke's Medical Center Donor Services2017-01-26 · FEI 1770151Storage temps./agitation
Often cited at the same inspection
Of the 42 inspections where FDA cited 21 CFR 640.25, the share where it also cited each of these sections.
- 21 CFR 606.100Standard operating procedures30 (71%)
- 21 CFR 606.160Records27 (64%)
- 21 CFR 606.20Personnel9 (21%)
- 21 CFR 606.60Equipment9 (21%)
- 21 CFR 606.171Reporting of product deviations by licensed manufacturers, unlicensed registered blood establishments, and transfusion services7 (17%)
- 21 CFR 606.65Supplies and reagents7 (17%)
Ask FDAgent about 21 CFR 640.25
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 640.25; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.