Kutol Products Company, Inc.
100 Partnership Way, Sharonville, Ohio, United States
FEI 1513988DUNS 004236139
FDA has 6 inspections on file for Kutol Products Company, Inc. in Sharonville, Ohio (FEI 1513988), from 2010 to 2025. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Four FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Nine regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is KUTOL PRODUCTS COMPANY (D-U-N-S 004236139).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 6, 2010–2025
- 1 OAI · 5 VAI · 0 NAI
- Inspections with 483 observations shown
- 6 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 4 requests, latest May 15, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Show 2 more citations
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing and holding of a drug product lack the education, training and experience required to perform their assigned functions.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Show 2 more citations
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not justified.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written in-process control procedures
Written procedures are not established that describe the tests to be conducted on appropriate samples of in-process materials of each batch.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used and parameters relevant to the operation.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure.
Show 5 more citations
Microbiological Contamination Exam
Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
Written calibration / inspection records not kept
Records of the of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure.
Label reconciliation discrepancies evaluation/investigation
Discrepancies found outside preset limits when reconciling the quantities of labeling issued, used and returned, were not investigated.
Review of representative number of batches
Written procedures are not established and followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Written calibration / inspection records not kept
Records of the inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
Show 7 more citations
Maintenance of Complaint File
Complaint procedures are deficient in that written complaint records are not maintained in a file designated for drug product complaints.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing, and holding of a drug product lack the training required to perform their assigned functions.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for completeness.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used and parameters relevant to the operation.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Quality control unit review of records
Drug product production and control records, are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, and packing of a drug product lack the training required to perform their assigned functions.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on May 15, 2026. Each one asked for a Form 483.
Inspection ending Mar 4, 2025OAI
4 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 21, 2025. FDAgent holds no copy that FDA posted.
- May 15, 2026FDA-FOIA-2026-4991Form 483· 1 of 5 sitesWithdrawn
- Oct 14, 2025FDA-FOIA-2025-11973Form 483· 1 of 5 sitesRecords released
- Aug 29, 2025FDA-FOIA-2025-10403Form 483Records released
- Apr 15, 2025FDA-FOIA-2025-3444Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 16 sections of 21 CFR in FDA’s published citations for this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance5 of 6
- 21 CFR 211.100Written procedures; deviations5 of 6
- 21 CFR 211.25Personnel qualifications3 of 6
- 21 CFR 211.192Production record review3 of 6
- 21 CFR 211.194Laboratory records3 of 6
- 21 CFR 211.198Complaint files3 of 6
- 21 CFR 211.22Responsibilities of quality control unit2 of 6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 6
Show all 16
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 6
- 21 CFR 211.165Testing and release for distribution2 of 6
- 21 CFR 211.180General requirements2 of 6
- 21 CFR 211.186Master production and control records2 of 6
- 21 CFR 211.80General requirements1 of 6
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 6
- 21 CFR 211.125Labeling issuance1 of 6
- 21 CFR 211.160General requirements1 of 6
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- KUTOL PRODUCTS COMPANYD-U-N-S 004236139
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1513988 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1513988. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.