Church & Dwight Canada Corp.
5485 Ferrier St, Mont-Royal, Canada
FEI 1000657351DUNS 253933600
Company: Church & Dwight Co., Inc. · Linked by exact D-U-N-S match (001211952) in FDA registration data
FDA has 5 inspections on file for Church & Dwight Canada Corp. in Mont-Royal, Canada (FEI 1000657351), from 2016 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 2 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
8 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.22(d).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and packing, through Dec 31, 2026. Its registrant, Church & Dwight Co., Inc. (D-U-N-S 001211952), has registered 3 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2016–2025
- 0 OAI · 4 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 5
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- 8 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Master production and control records, procedure
The preparation of your master production and control records was not described in a written procedure.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.
Test method modification records not maintained
Complete records are not maintained of any modification of an established method employed in testing.
Show 1 more citation
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program.
Buildings not maintained in good state of repair
Buildings used in the manufacturing of a drug product are not maintained in a good state of repair.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit3 of 3
- 21 CFR 211.58Maintenance1 of 3
- 21 CFR 211.160General requirements1 of 3
- 21 CFR 211.170Reserve samples1 of 3
- 21 CFR 211.182Equipment cleaning and use log1 of 3
- 21 CFR 211.186Master production and control records1 of 3
- 21 CFR 211.192Production record review1 of 3
- 21 CFR 211.194Laboratory records1 of 3
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1000657351, one row per refused product line.
8 refusals from 2021-04-02 to 2026-08-13 · charged NOT LISTED on 7, UNAPPROVED on 2 · FDA sample analysis on 1
FDA firm profile- 2026-08-13
CONDOM85HIS
NOT LISTED 502(o), 801(a)(3); MISBRANDING
Charge 9999973
Division of Northern Border ImportsSCS-0948362-7/10002/1
- 2026-04-10
TRIETHANOLAMINE (PHARMACEUTIC NECESSITY)55PY24
NOT LISTED 502(o), 801(a)(3); MISBRANDING
FDA sample analysis
Division of Northern Border Imports9DH-0078614-0/10003/1
- 2024-05-24
HYDROCORTISONE ACETATE (GLUCOCORTICOID)64LAM38
NOT LISTED 502(o), 801(a)(3); MISBRANDING
Division of Northern Border Imports9L7-1236564-7/41/1
- 2024-05-24
PRAMOXINE HCL (ANESTHETIC)60QBJ69
NOT LISTED 502(o), 801(a)(3); MISBRANDING
Division of Northern Border Imports9L7-1236564-7/31/1
- 2024-01-05
ANALGESIC, N.E.C.60LBJ99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northern Border Imports9DH-0057727-5/151/1
Show 3 more
- 2021-09-28
ANTI-EMETIC/NAUSEANT N.E.C.61TAM99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING
Division of Southwest ImportsAE9-0051598-0/21/1
- 2021-09-28
SIMETHICONE (ANTI-FLATULENT)61VAL01
NOT LISTED 502(o), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING
Division of Southwest ImportsAE9-0051598-0/11/1
- 2021-04-02
DIMENHYDRINATE (ANTI-EMETIC/NAUSEANT)61TAH06
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-1669116-4/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing
- Registration runs through
- Dec 31, 2026
- Registrant
- Church & Dwight Co., Inc.D-U-N-S 001211952
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Church & Dwight Co., Inc. (D-U-N-S 001211952) as the registrant for this site and the 3 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Church & Dwight Co., Inc.Old Fort, Ohio · FEI 15256478 inspections8latestJul 16, 2026VAINone on file
- Church & Dwight Co., Inc.Lakewood, New Jersey · FEI 22245496 inspections6latestOct 25, 2024VAINone on file
- Church & Dwight Co., Inc.Green River, Wyoming · FEI 17139025 inspections5latestAug 22, 2024NAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 1000657351 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 1000657351. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.