Hisamitsu Pharmaceutical Co., Inc.
408, Tashirodaikan-Machi, Tosu, Japan
FEI 1000266995DUNS 690539713
Company: Hisamitsu Pharmaceutical Co., Inc. · Linked by exact D-U-N-S match (690539713) in FDA registration data
FDA has 6 inspections on file for Hisamitsu Pharmaceutical Co., Inc. in Tosu, Japan (FEI 1000266995), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483.
3 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.160(b) and 21 CFR 211.22(d).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant, Hisamitsu Pharmaceutical Co., Inc. (D-U-N-S 690539713), has registered 1 other site.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2009–2025
- 0 OAI · 5 VAI · 1 NAI
- Inspections with 483 observations shown
- 4 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest Dec 2, 2025
- Warning letters
- None on file
- Import refusals
- 3 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components, drug product containers, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Equipment for Environmental Control
Equipment for adequate control over humidity is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.
Identification of each component or in-process material
Batch production and control records do not include the specific identification of each batch of component used for each batch of drug product produced.
Component addition checked by 2nd person
Each component is not added to a batch by one person and verified by a second person.
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed and documented at the time of performance.
In-process materials specifications
In-process specifications are not derived from previous acceptable process average and process variability estimates where possible.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Show 3 more citations
Sampling/testing of labeling/packaging materials
Labeling and packaging materials are not representatively sampled upon receipt and before use in packaging and labeling of a drug product.
Buildings not maintained in good state of repair
Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Dec 2, 2025. Each one asked for a Form 483.
Inspection ending Jul 4, 2025VAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Dec 11, 2025. FDAgent holds no copy that FDA posted.
- Dec 2, 2025FDA-FOIA-2025-13507Form 483· 1 of 5 sitesRecords released
Inspection date not given
2 requests. FDA released records in answer to a request for its Form 483 on Sep 19, 2025. FDAgent holds no copy that FDA posted.
- Sep 1, 2025FDA-FOIA-2025-10435Form 483Records released
- Aug 19, 2025FDA-FOIA-2025-10004Form 483Withdrawn
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 15 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements3 of 4
- 21 CFR 211.22Responsibilities of quality control unit2 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 4
- 21 CFR 211.188Batch production and control records2 of 4
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 4
- 21 CFR 211.58Maintenance1 of 4
- 21 CFR 211.100Written procedures; deviations1 of 4
- 21 CFR 211.101Charge-in of components1 of 4
Show all 15
- 21 CFR 211.122Materials examination and usage criteria1 of 4
- 21 CFR 211.166Stability testing1 of 4
- 21 CFR 211.170Reserve samples1 of 4
- 21 CFR 211.182Equipment cleaning and use log1 of 4
- 21 CFR 211.186Master production and control records1 of 4
- 21 CFR 211.192Production record review1 of 4
- 21 CFR 211.198Complaint files1 of 4
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1000266995, one row per refused product line.
3 refusals from 2020-05-12 to 2023-12-19 · charged UNAPPROVED on 2, NOT LISTED on 1 · no FDA sample analysis
FDA firm profile- 2023-12-19
MENTHOL (ANTI-PRURITIC)62MBD08
NOT LISTED 502(o), 801(a)(3); MISBRANDING
INCONSPICU 502(c), 801(a)(3); MISBRANDING
Division of Northern Border Imports9DH-0057382-9/51/1
- 2023-10-23
MENTHOL (ANTI-PRURITIC)62MBY08
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northern Border Imports98F-0086264-7/21/1
- 2020-05-12
KETOPROFEN (ANTI-INFLAMMATORY)62GCY46
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-6840357-4/21/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- Hisamitsu Pharmaceutical Co., Inc.D-U-N-S 690539713
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Hisamitsu Pharmaceutical Co., Inc. (D-U-N-S 690539713) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Hisamitsu Pharmaceutical Co., Inc.Utsunomiya, Japan · FEI 30087427803 inspections3latestJul 11, 2025VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 1000266995 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 1000266995. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.