Absolute Natural Blenders, Inc.
390 N Wickham Rd Ste F, Melbourne, Florida, United States
FEI 1000208724
FDA has one inspection on file for Absolute Natural Blenders, Inc. in Melbourne, Florida (FEI 1000208724). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 26 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2010
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance26 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Habits of good sanitation & health
Production personnel were not practicing good sanitation and health habits.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance and instructions for removal or obliteration of previous batch identification.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Show 21 more citations
Testing Calculations
Laboratory records are deficient in that they do not include all calculations performed during testing.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
input/output verification
Input to and output from the computer, related systems of formulas, and records or data are not checked for accuracy.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Actual yield, % of theoretical yield
The batch production and control records do not include a statement of the actual yield at appropriate stages of processing for each batch of drug product produced.
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of cleaning and sanitizing agents designed to prevent the contamination of drug products.
Retest of approved components/containers/closures
Approved components are not retested or reexamined as appropriate for identity, strength, quality and purity after storage for long periods with subsequent approval or rejection by the quality control unit.
Lab controls established, including changes
The establishment of specifications, standards, sampling plans, test procedures, and laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Distinctive ID or code not recorded in batch record
The batch records do not record the distinctive identification number, code, and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Instruments, apparatus, et. al. not meeting specs
The use of instruments not meeting established specifications was observed.
Contract drug products--lack of responsibility
The quality control unit lacks responsibility for approving or rejecting drug products processed, packed, and held under contract by another company.
Deviations from laboratory control requirements
Deviations from written specifications are not justified.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release.
Test methods
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established.
Sampling and testing plans not described
Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Adverse Drug Experience
Complaint procedures are deficient in that they do not include provisions that allow for the review to determine if the complaints represent serious and unexpected adverse drug experiences which are required to be reported to FDA.
Regulations FDA cited here
The 19 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.28Personnel responsibilities1 of 1
- 21 CFR 211.56Sanitation1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.87Retesting of approved components, drug product containers, and closures1 of 1
Show all 19
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.105Equipment identification1 of 1
- 21 CFR 211.125Labeling issuance1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.166Stability testing1 of 1
- 21 CFR 211.170Reserve samples1 of 1
- 21 CFR 211.180General requirements1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
- 21 CFR 211.194Laboratory records1 of 1
- 21 CFR 211.198Complaint files1 of 1
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000208724 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000208724. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.