FDA has 6 inspections on file for Universal Packaging Systems, Inc. in Chino, California (FEI 1000125370), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Nov 17, 2023. 17 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.

Three regulations were cited at more than one inspection: 21 CFR 211.100(a), 21 CFR 211.160(a) and 21 CFR 211.192.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is Paklab (D-U-N-S 177711082).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
6, 2009–2025
1 OAI · 3 VAI · 2 NAI
Inspections with 483 observations shown
4 of 6
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
3 requests, latest Nov 27, 2025
Warning letters
None on file
Import refusals
17 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. SOPs not followed / documented

      Written production and process control procedures are not documented at the time of performance.

    2. Approve or reject components, products

      The quality control unit lacks the responsibility and authority to approve and reject all components and drug products.

    3. Valid stability test methods

      The written stability program for drug products does not include meaningful test methods.

    4. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not established.

    5. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not at appropriate intervals to prevent that would alter the safety, identity, strength, quality or purity of the drug product.

    Show 1 more citation
    1. Stability sample storage conditions described

      The written stability program for drug products does not describe the storage conditions for samples retained for testing.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Following/documenting laboratory controls

      Established specifications and laboratory control mechanisms are not followed and documented at the time of performance.

    2. Written procedures not established/followed

      Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    5. Mfg / Processing Operations Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.

    Show 3 more citations
    1. Extent of discrepancy, failure investigations

      Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.

    2. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    3. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.

    2. Calibration/Inspection/Checking not done

      Routine checking of electronic equipment is not performed according to a written program designed to assure proper performance.

    3. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    4. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

    5. Component identification test

      Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.

  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Deviations from laboratory control requirements

      Deviations from written test procedures and laboratory mechanisms are not justified.

    2. No written record of investigation

      Written records are not always made of investigations into unexplained discrepancies.

    3. Lab controls established, including changes

      The establishment of specifications, test procedures, and laboratory control mechanisms including any changes thereto, are not reviewed and approved by the quality control unit.

    4. Establishment of calibration procedures

      Procedures describing the calibration of instruments, apparatus, gauges and recording devices are deficiently written or followed.

  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Nov 27, 2025. Each one asked for a Form 483.

  • Inspection ending May 29, 2025VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jul 29, 2025FDA-FOIA-2025-9183Form 483· 1 of 5 sitesClosed
  • Inspection ending Nov 17, 2023OAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Dec 5, 2025. FDAgent holds no copy that FDA posted.

    1. Nov 27, 2025FDA-FOIA-2025-13346Form 483Records released
    2. Jan 4, 2024FDA-FOIA-2024-130Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 12 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 6 inspections, with how many of them cited each.

Show all 12

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1000125370, one row per refused product line.

17 refusals from 2018-04-23 to 2021-03-02 · charged NOT LISTED on 15, FRNMFGREG on 6 · no FDA sample analysis

FDA firm profile
  • 2021-03-02

    TITANIUM DIOXIDE (PROTECTANT)65LBL11

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0052578-7/431/1

  • 2021-03-02

    THYROMIMETIC N.E.C.66LBL99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0052578-7/411/1

  • 2020-12-08

    TITANIUM DIOXIDE (PROTECTANT)65LBL11

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0052389-9/91/1

  • 2020-11-24

    THYROMIMETIC N.E.C.66LBL99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0052327-9/211/1

  • 2019-12-26

    THYROMIMETIC N.E.C.66LBL99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0050970-8/181/1

Show 12 more
  • 2019-05-08

    TITANIUM DIOXIDE (PROTECTANT)65LBL11

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0050129-1/181/1

  • 2019-03-29

    THYROMIMETIC N.E.C.66LBL99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0049934-8/931/1

  • 2019-03-29

    THYROMIMETIC N.E.C.66LBL99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0049934-8/641/1

  • 2019-03-29

    THYROMIMETIC N.E.C.66LBL99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0049934-8/221/1

  • 2019-03-29

    TITANIUM DIOXIDE (PROTECTANT)65LBL11

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0049934-8/111/1

  • 2019-03-25

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBY99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0049911-6/291/1

  • 2019-03-13

    TITANIUM DIOXIDE (PROTECTANT)65LBL11

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0050027-7/171/1

  • 2018-09-26

    THYROMIMETIC N.E.C.66LBL99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0048129-6/281/1

  • 2018-09-26

    TITANIUM DIOXIDE (PROTECTANT)65LBL11

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0048129-6/151/1

  • 2018-09-26

    TITANIUM DIOXIDE (PROTECTANT)65LBL11

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0047086-9/171/1

  • 2018-09-26

    TITANIUM DIOXIDE (PROTECTANT)65LBL11

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0046906-9/201/1

  • 2018-04-23

    THYROMIMETIC N.E.C.66LBL99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAV3-0047012-5/251/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2027
Registrant
PaklabD-U-N-S 177711082

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other FEIs recorded as Universal Packaging Systems, Inc.

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1000125370 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1000125370. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.