Skip to content

Pharmagen Laboratories, Inc Form 483, August 2013

FDA issued this Form 483 to Pharmagen Laboratories, Inc in Stamford, Connecticut (FEI 3009864179) at the end of a drug inspection that ended August 23, 2013. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Aug 23, 2013
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
3,799 days after the inspection
Facility
FEI 3009864179
Stamford, Connecticut

FDA's 13 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Signature and checking of records -- 2 persons

    The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.

  2. Test methods

    The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.

  3. Protective Apparel Not Worn

    Protective apparel is not worn as necessary to protect drug products from contamination.

  4. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  5. Training--operations, GMPs, written procedures

    Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.

  6. Lack of quality control unit

    There is no quality control unit.

  7. Written complaint record to be maintained at facility

    A written record of each complaint is not maintained in a file designated for drug product complaints at the facility where the drug product was manufactured, processed or packed.

  8. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

  9. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

  10. Calibration/Inspection/Checking not done

    Routine calibration and checking of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.

  11. Sanitation--buildings not clean, free of infestation

    Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

  12. Lack of written stability program

    There is no written testing program designed to assess the stability characteristics of drug products.

  13. Defined areas of adequate size for operations

    The control systems necessary to prevent contamination or mix-ups are deficient.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterOct 24, 2014CDER · 427 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3009864179, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.