Kilitch Healthcare India Limited Form 483, October 2023

FDA issued this Form 483 to Kilitch Healthcare India Limited in Navi Mumbai, India (FEI 3011853060) at the end of a drug inspection that ended October 20, 2023. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on March 28, 2024.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 29, 2023. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Oct 20, 2023
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Nov 29, 2023
40 days after the inspection
Facility
FEI 3011853060
Navi Mumbai, India

FDA's 14 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Scientifically sound laboratory controls

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

  2. Valid stability test methods

    The written stability program for drug products does not include meaningful test methods.

  3. Sanitation--buildings not clean, free of infestation

    Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

  4. Procedures for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

  5. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  6. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

  7. Complete test data included in records

    Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

  8. Component identity verification

    Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.

  9. Procedures not in writing, fully followed

    The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

  10. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  11. Changes to Procedures Not Reviewed, Approved

    Changes to written procedures are not reviewed and approved by the quality control unit.

  12. Prepared for each batch, include complete information

    Batch production and control records do not include complete information relating to the production and control of each batch.

  13. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  14. Following/documenting laboratory controls

    Established test procedures are not documented at the time of performance.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3011853060, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.