CTK OTC Laboratories LLC
1690 N Delilah St, Corona, California, United States
FEI 3014253278DUNS 119509846
FDA has 4 inspections on file for CTK OTC Laboratories LLC in Corona, California (FEI 3014253278), from 2018 to 2026. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Four of the seven FOIA requests for this site have asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Seven regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is CTK OTC Laboratories LLC (D-U-N-S 119509846).
Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 4, 2018–2026
- 2 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 4
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 7 requests, latest Aug 19, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Calibration/Inspection/Checking not done
Routine calibration and checking of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies.
Suitability of testing methods verified
The suitability of all testing methods is not verified under actual conditions of use.
Written in-process control procedures
Written procedures are not established and followed that describe the in-process controls to be conducted on appropriate samples of in-process materials of each batch.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Investigations made into any unexplained discrepancy
Batch production and control records do not include the results of any investigation made into any unexplained discrepancy, whether or not the batch of drug product had already been distributed.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Show 2 more citations
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its.
Written Procedures Not Followed
Written procedures are not followed for the approval and rejection of components.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance11 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written Procedures Not Followed
Written procedures are not followed for the sampling, testing, approval and rejection of components.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Defined areas of adequate size for operations
The separate or defined areas necessary to prevent contamination or mix-ups are deficient.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.
Show 6 more citations
Product flow through building is inadequate
The flow of components though the building is not designed to prevent contamination.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Approve or reject procedures or specs
The quality control unit lacks responsibility to approve all procedures or specifications impacting on the identity, strength, quality and purity of drug products.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Written record of investigation incomplete
Written records of investigations into the failure of a batch or any of its components to meet specifications do not include the conclusions and follow-up.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Seven requests to FDA under the Freedom of Information Act named this site, most recently on Aug 19, 2026. Each one asked for a Form 483.
Inspection ending May 4, 2026OAI
4 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Aug 11, 2026. FDAgent holds no copy that FDA posted.
- Aug 19, 2026FDA-FOIA-2026-8021Form 483Directed Requester to Publicly Available Information
- Aug 12, 2026FDA-FOIA-2026-7799Form 483· 1 of 2 sitesRecords released
- Aug 12, 2026FDA-FOIA-2026-7752Form 483· 1 of 3 sitesRecords released
- Jul 23, 2026FDA-FOIA-2026-7098Form 483· 1 of 5 sitesRecords released
Inspection ending Dec 31, 2024OAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 9, 2025. FDAgent holds no copy that FDA posted.
- Aug 22, 2025FDA-FOIA-2025-10108Form 483Records released
- Mar 27, 2025FDA-FOIA-2025-2834Form 483· 1 of 2 sitesClosed
Inspection date not given
1 request. FDA released records in answer to a request for its Form 483 + EIR on Feb 27, 2026. FDAgent holds no copy that FDA posted.
- Feb 24, 2026FDA-FOIA-2026-1922Form 483 + EIR· 1 of 6 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.63Equipment design, size, and location3 of 4
- 21 CFR 211.67Equipment cleaning and maintenance3 of 4
- 21 CFR 211.192Production record review3 of 4
- 21 CFR 211.25Personnel qualifications2 of 4
- 21 CFR 211.80General requirements2 of 4
- 21 CFR 211.180General requirements2 of 4
- 21 CFR 211.188Batch production and control records2 of 4
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
Show all 12
- 21 CFR 211.42Design and construction features1 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 4
- 21 CFR 211.194Laboratory records1 of 4
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- CTK OTC Laboratories LLCD-U-N-S 119509846
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014253278 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014253278. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.