FDA has one inspection on file for Waveform Inc in Marietta, Georgia (FEI 3012119287). It ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 16 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2016
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance16 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Strict control not exercised over labeling issued

      Strict control is not exercised over labeling issued for use in drug product labeling operations.

    2. Accurate reproduction

      The batch production and control records are deficient in that they are not an accurate reproduction of the appropriate master production or control record and checked for accuracy, dated, and signed.

    3. No written record of investigation

      Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.

    4. Test methods

      The accuracy , sensitivity , specificity and reproducibility of test methods have not been established and documented.

    5. Calculations performed are in the records

      Laboratory records do not include a record of all calculations performed in connection with the test.

    Show 11 more citations
    1. Calibration - at intervals, written program, remedial action

      The calibration of instruments and apparatus is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.

    2. GMP Training Frequency

      GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.

    3. Measured components for manufacturing

      Components for drug product manufacturing are not subdivided as appropriate.

    4. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    5. Establish reliability of supplier's C of A

      Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.

    6. Data secured in course of each test

      Laboratory records do not include a complete record of all data secured in the course of each test, including all graphs , charts and spectra from laboratory instrumentation, properly identified to show the specific component , in-process material , lot tested and drug product tested.

    7. Deviations from laboratory control requirements

      Deviations from written specifications , standards , sampling plans , test procedures and laboratory mechanisms are not recorded and justified.

    8. Sampling and testing procedures described

      Written specifications for laboratory controls do not include a description of the testing procedures used.

    9. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications , standards and test procedures designed to assure that components , in-process materials , labeling and drug products conform to appropriate standards of identity, strength, quality and purity.

    10. Component release checked by 2nd person

      Each container of component dispensed to manufacturing is not examined by a second person to assure that the weight or measure is correct as stated in the batch records.

    11. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

Regulations FDA cited here

The 10 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 10

Other FEIs recorded as Waveform Inc

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

  • Waveform IncFEI 3003630476Woodstock, Georgia, United States

    Last inspected 2015-10-29VAI

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3012119287 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3012119287. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.