FDA has one inspection on file for Waveform Inc in Marietta, Georgia (FEI 3012119287). It ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 16 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2016
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance16 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Accurate reproduction
The batch production and control records are deficient in that they are not an accurate reproduction of the appropriate master production or control record and checked for accuracy, dated, and signed.
No written record of investigation
Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
Test methods
The accuracy , sensitivity , specificity and reproducibility of test methods have not been established and documented.
Calculations performed are in the records
Laboratory records do not include a record of all calculations performed in connection with the test.
Show 11 more citations
Calibration - at intervals, written program, remedial action
The calibration of instruments and apparatus is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Measured components for manufacturing
Components for drug product manufacturing are not subdivided as appropriate.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Establish reliability of supplier's C of A
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
Data secured in course of each test
Laboratory records do not include a complete record of all data secured in the course of each test, including all graphs , charts and spectra from laboratory instrumentation, properly identified to show the specific component , in-process material , lot tested and drug product tested.
Deviations from laboratory control requirements
Deviations from written specifications , standards , sampling plans , test procedures and laboratory mechanisms are not recorded and justified.
Sampling and testing procedures described
Written specifications for laboratory controls do not include a description of the testing procedures used.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications , standards and test procedures designed to assure that components , in-process materials , labeling and drug products conform to appropriate standards of identity, strength, quality and purity.
Component release checked by 2nd person
Each container of component dispensed to manufacturing is not examined by a second person to assure that the weight or measure is correct as stated in the batch records.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.101Charge-in of components1 of 1
- 21 CFR 211.125Labeling issuance1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
Show all 10
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 211.194Laboratory records1 of 1
Other FEIs recorded as Waveform Inc
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Waveform IncFEI 3003630476Woodstock, Georgia, United States
Last inspected 2015-10-29VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012119287 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012119287. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.