FDA has 2 inspections on file for Waveform Inc in Woodstock, Georgia (FEI 3003630476), from 2011 to 2015. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 10 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.160(b)(4).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2011–2015
- 0 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate standards designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Written sanitation procedures not followed
Written procedures for sanitation are not followed.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.
Calibration - at intervals, written program, remedial action
The calibration of instruments, apparatus, gauges, and recording devices is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
Show 5 more citations
Calibration/Inspection/Checking not done
Routine calibration, inspection, and checking of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function and written procedures required by current good manufacturing practice regulations.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and completeness.
Deviations from laboratory control requirements
Deviations from written laboratory mechanisms are not justified.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals .
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.194Laboratory records2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.56Sanitation1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
- 21 CFR 211.192Production record review1 of 2
Other FEIs recorded as Waveform Inc
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Waveform IncFEI 3012119287Marietta, Georgia, United States
Last inspected 2016-02-19OAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003630476 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003630476. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.