Pine Pharmaceuticals LLC
355 Riverwalk Pkwy, Tonawanda, New York, United States
FEI 3010943533
FDA has 7 inspections on file for Pine Pharmaceuticals LLC in Tonawanda, New York (FEI 3010943533), from 2014 to 2025. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. One of the six FOIA requests for this site has asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.113(b) and 21 CFR 211.192.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 7, 2014–2025
- 5 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 6 of 7
- 2 posted 483s not matched to an inspection
- Requested under FOIA
- 6 requests, latest Jan 6, 2026
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to investigate unexplained discrepancies
OBSERVATIO 1 There is a failure to thoroughly review any unexplained discrepancy whether already distributed. Specifically, Your firm fail to adequately evaluate and limited to butincludingthe followingexamples, 1) Complaintinvestigation, COMP-2025 lot 79815-C, expiry 1/29/2025, was confirmed the presence of two cellulose particulates and three unidentified translucent fibers in the four returned vials. These four vials were (b) (4) you concluded that the batch was "essentially free from visible particulate matter" based on inspection of retain samples and characterized this incident 2024, representing (b) (4) of distributed AQL performed prior to release and complaint COMP-2025-0005 confirmed defects that were trussed by your quality Areplacementvialwasprovidedto the implemented. In addition, your firm analytical labreport. There is a failure to thoroughly review any unexplained discrepancy whether already distributed. Specifically, 2) Your firm released drug products despite inspection, basing these release decisions reinspections, second 100% AQL reinspections, a) (b) (4)n filled Bevacizumab 83436, expiration 1/15/2026, units). Your firm's specification 100% visual inspection of the integrity issues (loose caps) and Non-Conformance, NONC-2025-0426, lot should be reinspected. The additional container closure critical defect this event was negligible and investigation because the tightened second supporting that the batch was the justification that the issue removed from the batch. b) Moxifloxacin in Balanced Salt Solution overall critical defect reject rate critical defect limits is (b)(4) Conformance NONC-2025-0191 defect (partially crimped seals) 100% visual inspection in (b) (4) Load): specifically, failed its initial underwent a 100% targeted visual reinspection (particles), as these exceeded thedefects were identified duri□ Since the overall batch had 100% visual reinspection, how and underwent 100% targete d (container/closure) that were ex Your firm failed to reinspect 100% visual reinspection, although rejects, not container closure defect was never performed on load EL, results from the second 100 defects inspected for each loa c) (6) (4) filled Bevacizumab 1.25 into a syringe, lot 83478, ex rat e of (b)(4) specification for critical defect this incident under 100% visual inspection dislodged cap. The first A defects for a dislodged visual inspection was performed with defects for a dislodged cap found. A second AQL was performed on this second 100% visual reinspection, and received a pa firm stated in the risk Since the initial AQL failure due to visual detection the subsequent focused no defects observed during the tightened batch meets the required been no customer complaints after AQL, and corrective actions, such and updates to the (b) (4) implemented to prevent been mitigated and the firm released this lot wi to the identified defective units, which were removed
- Observation 2
Aseptic procedures not followed
OBSERVATION 2 Procedures designed to prevent microbiological contamination are not followed. Specifically, 1) On 11/4/2025, during the aseptic repackaging 84058, we observed your operator re ISO =i area and then extending their aseptic processing without sanitizing Behavior and Aseptic Technique," Rev. 2) During video review on 11/12/2025, the production of Calcium CL20 mg/mL (500 mL) inj, lot 83663, e (b) (4). For example, a. Your operator grabbed transfer tubing from ISO– space, brought it into ISO–1 space, and failed to sanitize the tube or their hands upon entry into ISO–1. b. While preparing the viable air monitors, your operator wiped the monitor with a wipe, set it back onto the table in ISO– space, and brought it into ISO–1 space without sanitizing again. c. Your operator rested their hands and wrists on the ergonomic support bar located within the ISO–1 area. The operator did not perform hand sanitization after this contact and before handling items within the ISO–1 area, including the wipes used to clean the port, a test beaker, and the (b)Your firm does not conduct routine environmental monitoring of trays used to stage materials, 3) including container closures, which are (b) placed into the ISO–1 classified area. The current procedure MWA-041, "Aseptic Processing Suite C Batch Specific Sample Locations," Rev. 08, fails to establish sampling requirements for these trays.
Show observations 3 to 5
- Observation 3
Unqualified visual inspection personnel
OBSERVATION 3 Employees engaged in the processing of a drug are not adequate for assigned functions. Specifically, Your manual visual inspection personnel are to your SOP-155, "Training and Qualification Product(s)", Revision 9, for visual inspection qualification which included (b)(4) (b)(4). Your firm failed to retroactively review your inspectors' previous qualifications to see if they align with the new procedure criteria. For example, review of one inspector's qualification revealed that, under (b)(4) would constitute (b)(4) due the (b)(4) visual inspection process inspections on these products since then, although the governing SOP was revised in August of 2025. The inspector was qualified on in March of 2025, and has continued to perform visual inspections on these products since then, although the governing SOP was revised in August of 2025.
- Observation 4
Actual yield and yield percentages missing
OBSERVATION 4 Actual yield and percentages of theoretical yield are not documented for the appropriate phase of processing of the drug product. Specifically, Visual inspection reject Limit calculations For example, your procedure, "Visual Inspection of Finished Product" SOP-061, rev. 23 states that defects will be verified by MQA and all falsely rejected units will be removed from the batch. However, defect rates will be based on quantity of confirmed defective units. Detection of particulate matter can vary between operator, color of fiber, size, and type of particle found.
- Observation 5
Inadequate validation and batch records
OBSERVATION 5 Your firm failed to establish adequate written procedures and validation to assure that the drug products have the identity, strength, quality, and purity represented to possess. Specifically, Your firm does not have validation performed for Phenylephrine HCL 2.5% Sterile Ophthalmic Solution (1...). Batch instructions include only directions for mix time and do not include mixing speed or other parameters. The process relies on operator training and QA verification. (b) (4) are not documented in the batch record and have not been validated.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing, packaging and holding of the drug product.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Mfg / Processing Operations Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Show 4 more citations
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Written in-process control procedures
Written procedures are not established that describe the in-process controls, tests and examinations to be conducted on appropriate samples of in-process materials of each batch.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
- FDCA 503B(b)(2)(A)
Outsourcing facility, compounded drug report follow up
Your outsourcing facility did not submit a report to FDA identifying the drugs compounded during the previous six month period.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to approve and reject all in process materials and drug products.
- FDCA 501(a)(2)(A)
Inadequate smoke studies
Smoke studies were inadequately performed under dynamic conditions.
Show 2 more citations
- FDCA 501(a)(2)(A)
Personnel, blocked or disrupted first air
Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.
- FDCA 501(a)(2)(A)
Production areas, difficult to clean/particle generating
Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling and drug products conform to appropriate standards of identity, strength, quality and purity.
Approve or reject procedures or specs
The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products.
Written calibration / inspection records not kept
Records of the calibration checks and inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Training , Education , Experience overall
Employees engaged in the processing of a drug product lack the training required to perform their assigned functions.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate OOS investigation and recalls
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. a). An investigation into out of specification test results for the potency of Vancomycin Injectable was not thorough. Lot 989-2 was released and partially distributed on 6/30/15 at 90.17% (specification [illegible]) as was lot 995-1 at 90.2% as was lot 996-2 at 90.65% with results obtained on 6/26/15. The entire batch for the three lots were stored in a freezer that lost power late on 6/26/15 and was out until 6/29/15. Samples for all three lots were retested for potency with respective results on 7/15/15 at 103.48, 86.01, and 104.1. Another lot, 1075-3 was found to be at 86.5% on 7/17/15 and was not released. The shelf life is 45 days frozen. One of the firm's conclusions was not to recall lots 989-2, 995-1, and 996-2 despite all three lots just at the lower limit of the potency and not being stored frozen for almost three days. Additionally, retest results stated above were variable with a failing test result and a later lot, 1075-3, failed for potency yet the firm concluded there was no need to recall. b). There have been several complaints concerning Bevacizumab (Avastin) syringes with crystalline structures seen on the needle. Dates of the complaint for this same defect were on 11/17/14, 7/30/15, 9/11/15 (three complaints that day) and 9/25/15 covering (b)(4) different lots. Each individual complaint was investigated, acknowledged the defect, and stated that "measures are being taken to prevent crystallization from occurring". Though complaints have been received over the past 11 months with most complaints occurring recently from the end of July throughout September, the firm has not fully instituted preventative or corrective actions. There is no written investigation addressing the reoccurrence of this defect; i.e. crystals on the Avastin needles.
- Observation 2
Aseptic area equipment maintenance/clutter
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. During processing of Bevacizumab 1.25 mg/0.05 mL lot 1740-2 on 10/05/15, we observed in the non-allergenic clean room the following: On the ISO 5 work area (in LAFW #1), there was clutter including a plastic bin containing various discarded articles as wrappers.
Show observations 3 to 5
- Observation 3
Unvalidated potency testing methods
For each batch of drug product, there shall be appropriate laboratory determination of satisfactory conformance to final specifications for the drug product, including the identity and strength of each active ingredient, prior to release. Released batches of the following products were tested for potency with testing methods that have not been validated: Vancomycin Intraocular Injection, Calcium Gluconate Topical gel, Ceftazidime Intraocular Injection, Mitomycin Ophthalmic Solution, and Moxifloxacin Intracameral Solution.
- Observation 4
Missing required label information
The labels and containers of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) and (B). Specifically, The following information is not found on some of your drug product labels: • The inactive ingredients, identified by established name and the quantity or proportion of each ingredient. Furthermore, the following information is not found on the container labels for some drug products you produce: Information to facilitate adverse event reporting: www.fda.gov/medwatch and 1-800-FDA-1088. Examples of drug product labels that do not contain this information include: • Calcium Gluconate Ophthalmic Irrigation 1% (500 ML) Solution • Calcium Gluconate (PF) Inhalation 2.5% (5 ML) Solution • Calcium Gluconate Topical 2.5% (60 GM) Gel • Ceftazidime Preservative Free SDV for Intraocular Injection 22.5 MG/ML Injectable • Mitomycin Solution for Ophthalmic Use 0.02% (0.2 MG/ML) • Moxifloxacin in BSS 150 MCG/0.1 ML Solution • Vancomycin Preservative Free SDV for Intraocular Injection 10 MG/ML • Vancomycin (Preservative Free) Pre-filled Syringe for Intraocular Injection 0.4 ML, 10 MG/ML • Vancomycin/Gentamicin Prefilled Syringe Solution for Intraocular Irrigation (TB Style Syringe) 1 MG-4 MG/ 0.12 ML
- Observation 5
Failure to report compounded products
Your outsourcing facility has not submitted a report to FDA identifying all products compounded during the previous six month period as required by section 503B(b)(2)(A). Examples of products that were compounded but not identified on the report submitted on June 29, 2015 include: • Sodium Hydroxide 10% Solution • Calcium Gluconate (PF) 10% Injectable • (b)(4) Capsules • Calcium Gluconate Ophthalmic Irrigation • Calcium Gluconate (PF) Inhalation 2.5%
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Six requests to FDA under the Freedom of Information Act named this site, most recently on Jan 6, 2026.
Inspection ending Nov 14, 2025OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jan 6, 2026FDA-FOIA-2026-169Form 483· 1 of 5 sitesRecords released
Inspection ending Sep 30, 2024OAI
3 requests. In the inspection history above. FDA has posted its Form 483.
- Aug 5, 2025FDA-FOIA-2025-8822Form 483· 1 of 2 sitesClosed over fees
- Jul 18, 2025FDA-FOIA-2025-8817Form 483· 1 of 2 sitesClosed over fees
- Dec 16, 2024FDA-FOIA-2024-11059Form 483· 1 of 2 sitesClosed
Inspection ending Sep 19, 2023OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Nov 9, 2023FDA-FOIA-2023-9989Form 483Closed
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Oct 21, 2024FDA-FOIA-2024-9330Inspection recordsClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.113Control of microbiological contamination4 of 4
- 21 CFR 211.192Production record review3 of 4
- 21 CFR 211.22Responsibilities of quality control unit2 of 4
- 21 CFR 211.25Personnel qualifications1 of 4
- 21 CFR 211.42Design and construction features1 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 4
- 21 CFR 211.100Written procedures; deviations1 of 4
- 21 CFR 211.103Calculation of yield1 of 4
Show all 11
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 4
- 21 CFR 211.125Labeling issuance1 of 4
- 21 CFR 211.160General requirements1 of 4
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010943533 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010943533. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.