Pine Pharmaceuticals, LLC Form 483, September 2024
FDA issued this Form 483 to Pine Pharmaceuticals, LLC in Tonawanda, New York (FEI 3010943533) at the end of a drug inspection that ended September 30, 2024. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Feb 12, 2025. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 30, 2024
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Feb 12, 2025
- 135 days after the inspection
FDA's 9 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing, packaging and holding of the drug product.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Mfg / Processing Operations Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Written in-process control procedures
Written procedures are not established that describe the in-process controls, tests and examinations to be conducted on appropriate samples of in-process materials of each batch.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3010943533, newest first.
- Form 483, November 2025Inspection ended Nov 14, 2025 · Posted Jan 22, 2026OAI
- Form 483, September 2023Inspection ended Sep 19, 2023 · Posted Nov 1, 2023OAI
- Form 483, May 2021Inspection ended May 14, 2021 · Posted Sep 24, 2021OAI
- Form 483, April 2018Inspection ended Apr 26, 2018 · Posted Jan 17, 2024VAI
- Form 483, October 2015Inspection ended Oct 9, 2015 · Posted Jan 17, 2024OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.