Skip to content

Cosmecca Korea Co., Ltd.

17-12 Daegeumro196beon-Gil, Daeso-Myeon, Eumseong, Korea (the Republic of)

FEI 3010165567

FDA has 4 inspections on file for Cosmecca Korea Co., Ltd. in Eumseong, Korea (the Republic of) (FEI 3010165567), from 2014 to 2026. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

The most recent OAI inspection ended on Sep 22, 2017. FDA issued a warning letter on (CDER). 28 import refusals are filed under this FEI, the latest on . FDA’s Import Alert 66-41 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
4, 2014–2026
1 OAI · 2 VAI · 1 NAI
Inspections with 483 observations shown
2 of 4
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
2 requests, latest Mar 31, 2026
Import refusals
28 refusals
Import alerts
66-41Red List
Matched on FDA’s firm name and street address

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and followed.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    3. Laboratory Test Method Verification

      Verification of the suitability of the testing methods is deficient in that they are not performed under actual conditions of use.

    4. Written in-process control procedures

      Written procedures are not established and followed that describe the in-process controls, tests and examinations to be conducted on appropriate samples of in-process materials of each batch.

    5. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    Show 5 more citations
    1. Following/documenting laboratory controls

      Established test procedures are not documented at the time of performance.

    2. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    3. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    4. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested nor are records of such data maintained to determine an appropriate expiration date.

    2. Backup file not maintained

      Failure to maintain a backup file of data entered into the computer or related system.

    3. Test method modification records do not include

      Records maintained of any modification of an established method employed in testing do not include the data to verify that the modification produced results that are at least as accurate and reliable for the material being tested as the established method.

    4. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    5. Written in-process control procedures

      Written procedures are not established that describe the in-process controls, tests, and examinations to be conducted on appropriate samples of in-process materials of each batch.

    Show 8 more citations
    1. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

    2. Training , Education , Experience overall

      Employees engaged in the processing and holding of a drug product lack the education required to perform their assigned functions.

    3. Reprocessing procedures not written or followed

      Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not followed.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    5. Distinctive ID or code not recorded in batch record

      The batch records do not record the distinctive identification number to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.

    6. Calibration/Inspection/Checking not done

      Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance.

    7. Actual vs. theoretical yields not determined

      Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of packaging of the drug product.

    8. Examination of packaging and labeling

      Examination of packaging and labeling materials for suitability and correctness before packaging operations is not documented in the batch production records.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Mar 31, 2026. Each one asked for a Form 483.

  • Inspection ending Sep 13, 2024VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 + EIR on Mar 18, 2026. FDAgent holds no copy that FDA posted.

    1. Mar 12, 2026FDA-FOIA-2026-2406Form 483 + EIR· 1 of 9 sitesRecords released
  • Inspection date not given

    1 request. FDA released records in answer to a request for its Form 483 + EIR on Apr 6, 2026. FDAgent holds no copy that FDA posted.

    1. Mar 31, 2026FDA-FOIA-2026-3116Form 483 + EIR· 1 of 3 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 14 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 4 inspections, with how many of them cited each.

Show all 14

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3010165567, one row per refused product line.

28 refusals from 2018-07-19 to 2026-08-25 · charged UNAPPROVED on 13, NOT LISTED on 12 · no FDA sample analysis

FDA firm profile
  • 2026-08-25

    HOMOSALATE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBL05

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast Imports1FX-6621337-2/10002/7

  • 2026-08-07

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PDY99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports1FX-7977132-5/10002/1

  • 2026-08-06

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBJ99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-0766900-4/10002/1

  • 2026-07-24

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBY99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAEK-0842037-3/10002/1

  • 2026-07-20

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBY99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-0862453-7/10002/1

Show 23 more
  • 2026-07-20

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBY99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-0842091-0/10002/1

  • 2026-07-10

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBJ99

    LACKS N/C 502(b)(2), 801(a)(3); MISBRANDING

    INCONSPICU 502(c), 801(a)(3); MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-0768673-5/10002/1

  • 2026-04-23

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBY99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-0353042-4/10002/1

  • 2026-04-23

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBY99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-0353039-0/10002/1

  • 2026-01-22

    PROTECTANT N.E.C.65LBJ99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAEK-9138795-9/10002/1

  • 2026-01-22

    PROTECTANT N.E.C.65LBJ99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsAEK-9138785-0/10002/1

  • 2025-12-01

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBY99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of West Coast Imports799-8511249-1/10002/2

  • 2025-10-09

    HOMOSALATE (ULTRAVIOLET SCREEN/SUNSCREEN)66PIL05

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-7736331-3/10002/1

  • 2025-08-13

    EXHIBITS - OTHER DRUG RELATED ITEMS N.E.C.66YCY99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-7398776-8/12/1

  • 2025-01-17

    MISCELLANEOUS PATENT MEDICINES, ETC.66VAY99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of West Coast Imports9G5-3019698-5/11/1

  • 2024-08-16

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PAY99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southeast ImportsBTF-2244014-9/51/1

  • 2024-08-16

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PAY99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southeast ImportsBTF-2244014-9/41/1

  • 2024-08-16

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PAY99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southeast ImportsBTF-2244014-9/31/1

  • 2024-07-30

    OCTOCRYLENE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBJ16

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southeast ImportsAEK-5464205-1/31/1

  • 2024-07-30

    OCTOCRYLENE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBJ16

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southeast ImportsAEK-5464205-1/21/1

  • 2024-07-30

    OCTOCRYLENE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBJ16

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southeast ImportsAEK-5464205-1/11/1

  • 2024-04-10

    EXHIBITS - OTHER DRUG RELATED ITEMS N.E.C.66YBY99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southeast Imports799-0265090-3/11/1

  • 2024-01-23

    MISCELLANEOUS PATENT MEDICINES, ETC.66VBY99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northeast ImportsEDY-1804628-3/3431/1

  • 2023-09-15

    MISCELLANEOUS PATENT MEDICINES, ETC.66VBJ99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of West Coast ImportsASW-0142840-7/51/1

  • 2022-02-10

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBY99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of West Coast Imports8BS-1709996-7/121/1

  • 2022-02-10

    ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBY99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING

    DRUG NAME 502(e)(1); 801(a)(3); Misbranding

    Division of West Coast Imports8BS-1709996-7/111/1

  • 2019-01-15

    MISCELLANEOUS PATENT MEDICINES, ETC.66VAY99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northeast Imports442-6613674-4/21/1

  • 2018-07-19

    PROTECTANT N.E.C.65LAY99

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of West Coast ImportsBNX-0006996-3/21/11

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-41Red ListDetention Without Physical Examination of Unapproved New Drugs Promoted In The U.S.Import alert pageAlert on fda.gov

    Date published 2016-06-24

    FDA’s entry
    Cosmecca Korea Co., Ltd. · 17-12 Daegeumro196beon-Gil, Daeso-Myeon, Eumseong, Chungcheongbuk KOREA (THE REPUBLIC OF)
    FDA’s inspection record for FEI 3010165567
    Cosmecca Korea Co., Ltd. · 17-12 Daegeumro196beon-Gil, Daeso-Myeon, Eumseong, Korea (the Republic of)

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    23 products

    • 53 G - - 03Foundations (Makeup Preparations, not for Eyes)
    • 53 G - - 03Foundations (Makeup Preparations, not for Eyes)
    • 53 G - - 99Other Makeup Preparation, not for the Eyes, N.E.C.
    Show 20 more products
    • 53 G - - 99Other Makeup Preparation, not for the Eyes, N.E.C.
    • 53 L - - 01Cleansing (Cold Creams, Cleansing Lotions, Liquids, Pads) (Skin Care Preparations)
    • 53 L - - 03Face,Body,and Hand (excluding Shaving Preparations) (Skin Care Preparations)
    • 53 L - - 03Face,Body,and Hand (excluding Shaving Preparations) (Skin Care Preparations)
    • 53 L - - 03Face,Body,and Hand (excluding Shaving Preparations) (Skin Care Preparations)
    • 53 L - - 03Face,Body,and Hand (excluding Shaving Preparations) (Skin Care Preparations)
    • 53 L - - 03Face,Body,and Hand (excluding Shaving Preparations) (Skin Care Preparations)
    • 53 L - - 03Face,Body,and Hand (excluding Shaving Preparations) (Skin Care Preparations)
    • 53 L - - 06Moisturizing (Skin Care Preparations)
    • 53 L - - 06Moisturizing (Skin Care Preparations)
    • 53 L - - 08Paste Masks (Mud Packs) (Skin Care Preparations)
    • 53 L - - 09Skin Fresheners (Skin Care Preparations)
    • 53 L - - 10Wrinkle Smoothing (Skin Care Preparations)
    • 53 L - - 10Wrinkle Smoothing (Skin Care Preparations)
    • 53 L - - 99Other Skin Care Preparations, N.E.C.
    • 53 L - - 99Other Skin Care Preparations, N.E.C.
    • 53 Y - - 99Other Cosmetic and Cosmetic Products, N.E.C.

    3 more products on the alert page.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010165567 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010165567. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.