Skip to content

Pallimed Solutions, Inc.

400 W Cummings Park, Woburn, Massachusetts, United States

FEI 3010084286

FDA has one inspection on file for Pallimed Solutions, Inc. in Woburn, Massachusetts (FEI 3010084286). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 13 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2013
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    2. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    3. Buildings not maintained in good state of repair

      Buildings used in the processing, packing, and holding of a drug product are not maintained in a good state of repair.

    4. Containers & Closures Clean, Sterilized, Pyrogen-free

      Drug product containers and closures were not clean and sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.

    5. Clothing appropriate for duties performed

      Clothing of personnel engaged in the processing, packing, and holding of drug products is not appropriate for the duties they perform.

    Show 8 more citations
    1. Approve or reject procedures or specs

      The quality control unit lacks responsibility to reject all procedures or specifications impacting on the identity, strength, quality, and purity of drug products.

    2. Adequate space lacking to prevent mix-ups and contamination

      The building lacks adequate space for the orderly placement of equipment and materials to prevent mix-ups between drug product containers, closures, and drug products and to prevent contamination.

    3. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    4. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    5. Equipment for Environmental Control

      Equipment for adequate control over air pressure is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.

    6. Aseptic Processing Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.

    7. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    8. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 11

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010084286 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010084286. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.