Trademark Cosmetics Inc
545 Columbia Ave, Riverside, California, United States
FEI 3010034367
FDA has 4 inspections on file for Trademark Cosmetics Inc in Riverside, California (FEI 3010034367), from 2008 to 2021. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 10 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.105(b), 21 CFR 211.166(b) and 21 CFR 211.100(a).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2008–2021
- 0 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 4
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
Adequate number of batches on stability
An adequate number of batches of each drug product are not tested nor are records of such data maintained to determine an appropriate expiration date.
Distinctive ID or code not recorded in batch record
The batch records do not record the distinctive identification number, code and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Show 5 more citations
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred.
Reserve samples identified, representative, stored
Reserve drug product samples are not appropriately identified and retained and stored under conditions consistent with product labeling.
Quarantine of Rejected Components et. al.
Rejected components, drug product containers and closures are not controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Adequate number of batches on stability
An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Following/documenting laboratory controls
Established sampling plans and test procedures are not followed and documented at the time of performance.
Distinctive ID or code not recorded in batch record
The batch records do not record the distinctive identification number to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
Show 1 more citation
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit and reviewed and approved by the quality control unit.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance2 of 3
- 21 CFR 211.100Written procedures; deviations2 of 3
- 21 CFR 211.105Equipment identification2 of 3
- 21 CFR 211.166Stability testing2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.58Maintenance1 of 3
- 21 CFR 211.63Equipment design, size, and location1 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 3
Show all 12
- 21 CFR 211.89Rejected components, drug product containers, and closures1 of 3
- 21 CFR 211.160General requirements1 of 3
- 21 CFR 211.165Testing and release for distribution1 of 3
- 21 CFR 211.170Reserve samples1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010034367 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010034367. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.