Henan Kangdi Medical Devices Co. Ltd
Sme Pioneer Park, No. 4 2nd Area, Zhoukou, China
FEI 3009271465DUNS 421288241
FDA has 2 inspections on file for Henan Kangdi Medical Devices Co. Ltd in Zhoukou, China (FEI 3009271465), from 2016 to 2019. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
4 import refusals are filed under this FEI, the latest on . FDA’s Red Lists for Import Alerts 66-40 and 66-41 name this firm at this address. FDA printed no FEI on the entries. No court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is Henan Kangdi Medical Devices Co. Ltd. (D-U-N-S 421288241).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2016–2019
- 1 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 2
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- 4 refusals
- Import alerts
- 66-40, 66-41Red List
- Matched on FDA’s firm name and street address
- Drug establishment registration
- Through
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Quarantine of Rejected Components et. al.
Rejected components, drug product containers and closures are not controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Distinctive ID or code not recorded in batch record
The batch records do not record the distinctive identification number, code and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
Incoming material area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the receipt, identification, storage, and withholding from use of components, drug product containers, closures and labeling pending sampling, testing, or examination by the quality control unit before release for manufacturing or packaging.
Show 8 more citations
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing and packing of a drug product are not maintained in a good state of repair.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, packing and holding.
Washing and toilet facilities are deficient
Washing and toilet facilities lack hot and cold water, soap or detergent, air driers or single-service towels and cleanliness.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and of adequate size to facilitate operations for its intended use and cleaning and maintenance.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.52Washing and toilet facilities1 of 1
- 21 CFR 211.58Maintenance1 of 1
- 21 CFR 211.63Equipment design, size, and location1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.89Rejected components, drug product containers, and closures1 of 1
Show all 13
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.105Equipment identification1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.180General requirements1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3009271465, one row per refused product line.
4 refusals from 2017-06-14 to 2019-12-13 · charged NOT LISTED on 2, DRUG GMPS on 1 · no FDA sample analysis
FDA firm profile- 2019-12-13
LIDOCAINE (ANESTHETIC)60QBY67
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of West Coast ImportsM34-2224793-2/11/1
- 2019-10-28
MISCELLANEOUS PATENT MEDICINES, ETC.66VDY99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
INCONSPICU 502(c), 801(a)(3); MISBRANDING
Division of Northeast Imports051-0227077-3/11/2
- 2017-07-12
EXHIBITS - OTHER DRUG RELATED ITEMS N.E.C.66YBD99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsDY2-0049306-1/11/1
- 2017-06-14
TAPE AND BANDAGE, ADHESIVE79KGX
NOT LISTED 502(o), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
NO 510(K) 801(a)(3); 502(o) Misbranding
Division of Southeast Imports799-0339523-1/11/1
Import alerts
FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.
- 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov
Date published 2019-10-25
- FDA’s entry
- Henan Kangdi Medical Devices Co. Ltd · Sme Pioneer Park, No. 4 2nd Area, Zhoukou, Henan CHINA
- FDA’s inspection record for FEI 3009271465
- Henan Kangdi Medical Devices Co. Ltd · Sme Pioneer Park, No. 4 2nd Area, Zhoukou, China
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
13 products
- 53 L - - 99Other Skin Care Preparations, N.E.C.
- 55 - - - --Pharm Necess & Ctnr For Drug/Bio
- 56 - - - --Antibiotics (Human/Animal)
Show 10 more products
- 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
- 60 - - - --Human and Animal Drugs
- 61 - - - --Human and Animal Drugs
- 62 - - - --Human and Animal Drugs
- 63 - - - --Human and Animal Drugs
- 64 - - - --Human and Animal Drugs
- 65 - - - --Human and Animal Drugs
- 66 - - - --Human and Animal Drugs
- 79 K - - GXTape And Bandage, Adhesive
- 89 I - - MDPack, Hot Or Cold, Disposable
- 66-41Red ListDetention Without Physical Examination of Unapproved New Drugs Promoted In The U.S.Import alert pageAlert on fda.gov
Date published 2012-06-08
- FDA’s entry
- Henan Kangdi Medical Devices Co. Ltd · Sme Pioneer Park, No. 4 2nd Area, Zhoukou, Henan CHINA
- FDA’s inspection record for FEI 3009271465
- Henan Kangdi Medical Devices Co. Ltd · Sme Pioneer Park, No. 4 2nd Area, Zhoukou, China
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
4 products
- 53 L - - 01Cleansing (Cold Creams, Cleansing Lotions, Liquids, Pads) (Skin Care Preparations)
- 53 L - - 99Other Skin Care Preparations, N.E.C.
- 66 V - - 99Miscellaneous Patent Medicines, Etc.
Show 1 more products
- 66 V - - 99Miscellaneous Patent Medicines, Etc.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- Henan Kangdi Medical Devices Co. Ltd.D-U-N-S 421288241
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3009271465 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3009271465. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.