Skip to content

Regrowth, LLC

11836 E. Washington Blvd., Suite # B, Whittier, California, United States

FEI 3008812208

FDA has one inspection on file for Regrowth, LLC in Whittier, California (FEI 3008812208). It ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

FDA published 17 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
1, in 2011
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upDrugs · Unapproved and Misbranded Drugs17 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

    2. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    3. Lack of quality control unit

      There is no quality control unit.

    4. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    5. Prepared for each batch, include complete information

      Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.

    Show 12 more citations
    1. Control procedures to monitor and validate performance

      Control procedures are not established which of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    2. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Examination of issued labels

      Labeling materials issued for a batch were not carefully examined for identity and conformity to the labeling specified in the master or batch production records.

    4. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    5. Retest of approved components/containers/closures

      Approved components are not retested or reexamined as appropriate for identity, strength, quality and purity after storage for long periods with subsequent approval or rejection by the quality control unit.

    6. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    7. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    8. Procedures to be written and followed

      Procedures describing the handling of all written and oral complaints regarding a drug product are not established and written.

    9. Incoming lots - conformance to written specs-

      Laboratory controls do not include determination of conformance to appropriate written specifications for the acceptance of each lot within each shipment of components, drug product containers, closures, in-process materials, labeling, and drug products used in the manufacture, processing, packing, or holding of drug products.

    10. Lot or control number assigned

      The drug product is not identified with a lot or control number that permits the determination of the history of the manufacture and control of the batch.

    11. Calibration/Inspection/Checking not done

      Routine calibration, inspection, and checking of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.

    12. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

Regulations FDA cited here

The 17 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 17

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3008812208 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3008812208. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.