Aidapak Services, LLC
14301 SE 1st St, Vancouver, Washington, United States
FEI 3008673824
FDA has 3 inspections on file for Aidapak Services, LLC in Vancouver, Washington (FEI 3008673824), from 2011 to 2013. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 9 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2011–2013
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Examination of packaging and labeling
Examination of packaging and labeling materials for suitability and correctness before packaging operations is not performed and not documented in the batch production records.
Procedures are written, and followed
Procedures designed to assure that correct labels are used for drug products are not written and followed.
Packaging line inspection before use
Inspection of the packaging and labeling facilities immediately before use is not done to assure that all drug products have been removed from previous operations.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Show 4 more citations
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Packaging line inspection after use
Inspection of the packaging and labeling facilities is not done after use to assure that materials not suitable for subsequent operations have been removed.
Buildings not maintained in good state of repair
Buildings used in the packing and holding of a drug product are not maintained in a good state of repair.
Reserve samples identified, representative, stored
Reserve drug product samples are not appropriately identified.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Procedures are written, and followed
Procedures designed to assure that correct labels are used for drug products are not followed.
Component Test Records
The drug product container and closure records do not include the results of tests or examinations performed and the conclusions derived from tests or examinations performed.
Written Procedures Not Followed
Written procedures are not followed for the receipt, identification, storage, handling, sampling, testing, approval, and rejection of drug product containers and closures.
Clothing appropriate for duties performed
Clothing of personnel engaged in the packing and holding of drug products is not appropriate for the duties they perform.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures Written and Followed
Procedures describing in sufficient detail the controls employed for the issuance of labeling are not followed.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Calibration/Inspection/Checking not done
Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.
Penicillin air handling systems not kept separate
Air-handling systems for the packing of penicillin are not completely separate from those for other drug products for human use.
Show 8 more citations
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Defined areas of adequate size for operations
The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Cleaning/maintenance records not kept
Records are not kept for the cleaning and sanitizing of equipment.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Penicillin processing area not kept separate
The operations relating to the packing of penicillin are not performed in facilities separate from those used for other drug products for human use.
Failing to test for penicillin cross-contamination
Non-penicillin drug products were not tested for the presence of penicillin, when a reasonable possibility existed that a non-penicillin drug product has been exposed to a cross-contamination with penicillin.
Regulations FDA cited here
The 16 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.25Personnel qualifications2 of 3
- 21 CFR 211.67Equipment cleaning and maintenance2 of 3
- 21 CFR 211.125Labeling issuance2 of 3
- 21 CFR 211.130Packaging and labeling operations2 of 3
- 21 CFR 211.28Personnel responsibilities1 of 3
- 21 CFR 211.42Design and construction features1 of 3
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 3
- 21 CFR 211.58Maintenance1 of 3
Show all 16
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
- 21 CFR 211.166Stability testing1 of 3
- 21 CFR 211.170Reserve samples1 of 3
- 21 CFR 211.176Penicillin contamination1 of 3
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 3
- 21 CFR 211.192Production record review1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3008673824 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3008673824. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.