Skip to content

Solupharm Pharmazeutische Erzeugnisse Gmbh

Industriestr. 3, Melsungen, Germany

FEI 3008255368DUNS 316875129

FDA has 5 inspections on file for Solupharm Pharmazeutische Erzeugnisse Gmbh in Melsungen, Germany (FEI 3008255368), from 2011 to 2022. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.

2 import refusals are filed under this FEI, the latest on . FDA’s Import Alert 66-41 Red List names this firm at this address. FDA printed no FEI on the entry. No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis and sterilization, through Dec 31, 2027. Its registrant is Solupharm Pharmazeutische Erzeugnisse GmbH (D-U-N-S 316875129).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
5, 2011–2022
0 OAI · 4 VAI · 1 NAI
Inspections with 483 observations shown
2 of 5
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
2 refusals
Import alerts
66-41Red List
Matched on FDA’s firm name and street address
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.

    2. Manufacturing Instructions and Specifications

      The master production and control records are deficient in that they do not include complete control and instructions.

    3. Complete Test Data

      Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

    3. Deviations of production time limits

      Deviations from production time limits are not justified.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Regulations FDA cited here

The 7 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 5 inspections, with how many of them cited each.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3008255368, one row per refused product line.

2 refusals from 2022-01-25 to 2022-09-15 · charged UNAPPROVED on 2 · no FDA sample analysis

FDA firm profile
  • 2022-09-15

    LIDOCAINE HCL (ANESTHETIC)60QCU40

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-0800289-2/11/1

  • 2022-01-25

    REPLENISHER N.E.C.65RCP99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-6613355-4/11/1

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-41Red ListDetention Without Physical Examination of Unapproved New Drugs Promoted In The U.S.Import alert pageAlert on fda.gov

    Date published 2020-06-15

    FDA’s entry
    Solupharm Pharmazeutische Erzeugnisse Gmbh · Industriestr. 3, Melsungen, Hesse GERMANY
    FDA’s inspection record for FEI 3008255368
    Solupharm Pharmazeutische Erzeugnisse Gmbh · Industriestr. 3, Melsungen, Germany

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    41 products

    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    Show 38 more products
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    • 60 - - - --Human and Animal Drugs
    • 60 - - - --Human and Animal Drugs
    • 60 - - - --Human and Animal Drugs
    • 60 - - - --Human and Animal Drugs
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs

    21 more products on the alert page.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis, sterilization
Registration runs through
Dec 31, 2027
Registrant
Solupharm Pharmazeutische Erzeugnisse GmbHD-U-N-S 316875129

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3008255368 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3008255368. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.