Skip to content

Axcentria Pharmaceuticals LLC

1836 Stout Dr Ste 2, Warminster, Pennsylvania, United States

FEI 3008062657

FDA has 2 inspections on file for Axcentria Pharmaceuticals LLC in Warminster, Pennsylvania (FEI 3008062657), from 2011 to 2014. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 11 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.22(d) and 21 CFR 211.84(a).

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2011–2014
0 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance11 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    2. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.

    3. Theoretical Yield and Percentages

      The master production and control records are deficient in that they do not include a statement of theoretical yield and minimum, maximum, and yield percentages.

    4. Approve or reject procedures or specs

      The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality, and purity of drug products.

    5. Failing drug products not rejected

      Drug products failing to meet established specifications and quality control criteria are not rejected.

    Show 6 more citations
    1. Components withheld from use pending release

      Each lot of components is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.

    2. Review of representative number of batches

      Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    3. Valid stability test methods

      The written stability program for drug products does not include reliable, meaningful, and specific test methods.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    5. Calculations performed are in the records

      Laboratory records do not include a record of all calculations performed in connection with the test.

    6. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Components withheld from use pending release

      Each lot of components is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in written procedures required by current good manufacturing practice regulations.

    4. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    5. Labeling control records including specimens or copies

      Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.

    Show 1 more citation
    1. Representative samples after completion

      Samples of representative units were not collected and visually examined for correct labeling at the completion of finishing operations.

Regulations FDA cited here

The 14 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.

Show all 14

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3008062657 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3008062657. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.