Premier Pharmacy Labs Inc
8265 Commercial Way, Weeki Wachee, Florida, United States
FEI 3007271263
FDA has 3 inspections on file for Premier Pharmacy Labs Inc in Weeki Wachee, Florida (FEI 3007271263), from 2014 to 2019. The latest ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Jul 25, 2019 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 15 citations from this inspection. They are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Six regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 3, 2014–2019
- 3 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 3 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance15 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Floors, walls, ceiling surfaces
Aseptic processing areas are deficient in that floors, walls and ceilings are not smooth and/or hard surfaces that are easily cleanable.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Results not used for expiration dates, storage cond.
Results of stability testing are not used in determining appropriate storage conditions and expiration dates.
Show 10 more citations
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
- FDCA 501(a)(2)(A)
Highly potent drugs, prevention of cross-contamination
You produced highly potent drugs without providing adequate containment, segregation, cleaning of work surfaces, cleaning of utensils and cleaning of personnel to prevent cross-contamination.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Temperature / Humidity Controls
Aseptic processing areas are deficient regarding temperature and humidity controls.
- FDCA 503B(a)(10)
Container label, outsourcer facility
The container labels of your outsourcing facility's drug products are deficient.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance11 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate ISO 5 air/HEPA control
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, a. Your firm has no procedures in place to describe the requirements and acceptance criteria for the HEPA Filters certification for ISO 5 areas available onsite (ISO 5 Laminar Flow Hood and ISO 5 area), used for compounding operations, or evaluation of airflow pattern studies (smoke studies) reported as part of the (b)(4) certification process of all areas. b. Airflow pattern studies (smoke studies) executed and included with the most recent certification exercise conducted in (b)(4) (reported to be conducted under similar conditions as to previous exercise conducted in (b)(4)) was found inadequate in that: 1) The video of the smoke studies conducted on laminar airflow working hood (LAFW) in which the (b)(4) machine is located showed non-unidirectional and turbulent air over the critical ISO 5 zone (b)(4). Your firm failed to recognize the [illegible] and poor air control and did not implement corrective and preventive action. A total of [illegible] batches of various ophthalmic drug products have been produced in this equipment within the last 90 days. 2) Areas depicted in videos included and failed to include evidence of smoke pattern in the (ISO 5 Area), including at rest/dynamic conditions of routine interventions such [illegible].
- Observation 2
Insufficient separation between cleanrooms
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations. Specifically, laminar air flow working hood (LAFW) (b)(4) is located in (b)(4) Cleanrooms, which is not a suitable location to prevent cross-contamination from personnel walking between rooms. During aseptic operations on 6/6/16, it was observed that the operator from Cleanroom (b)(4) walked between cleanrooms and behind the operator in LAFW numerous times while aseptic operations of injectable drug products were ongoing in LAFW.
Show observations 3 to 11
- Observation 3
Inadequate visual inspection criteria
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification as a condition for their approval and release. Specifically, SOP 820.4 "Particulate Testing, Visual Inspection and Reconciliation for Sterile Preparations" does not require 100% visual inspection of sterile injectable and ophthalmic drug products before release; instead (b)(4) is visually inspected. In addition, there are no criteria for acceptable levels of defects and the type and number of defects observed during visual inspection are not always documented in the batch record at the time of performance. For example, on 6/6/16 upon inspection of the batch record of quarantined Proparacaine unit dose 0.5% solution, lot PR0060216NWAB, repackaged on 6/2/16 and pending test results, we found a leaking vial and a vial with a red fiber that were segregated as defective on 6/2/16; however, the batch record only documented a (b)(4) visual inspection of [illegible] of which (b)(4) passed. There was no investigation or documentation of 100% visual inspection of the rest of the vials to ensure similar defects were not present (product was [illegible] (b)(4) machine).
- Observation 4
Inadequate equipment qualification and maintenance
Equipment and utensils are not maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, the (b)(4) (b)(4) was not properly qualified during installation to determine appropriate (b)(4) and is not maintained at appropriate intervals to ensure proper performance. A failed media fill on (b)(4) and CAPA 15004, 1/15/15, issued for leaking (b)(4) did not identify adequate corrective and preventive action and a surface sample of 13 CFUs (spec (b)(4)) on the equipment on 9/12/15 was not investigated.
- Observation 5
No re-use date/testing for vials
Approved drug product containers are not retested or reexamined as appropriate for identity, strength, quality and purity after storage for long periods and exposure to conditions that might have an adverse event with subsequent approval or rejection by the quality control unit. Specifically, the (b)(4) sterile plastic vials (droppers) used for ophthalmic drug products are received in (b)(4) containing (b)(4) which is re-sealed (b)(4) if all vials are not used within a batch (range in size from approximately (b)(4)). However, your firm did not establish an acceptable re-use date of opened vials and lacked test data to ensure the vials remain sterile during handling with gloved hands and in the re-sealed bag which is stored in an ISO 7 area. In addition, your firm failed to protect empty vials from particulates generated by using (b)(4) within the ISO 5 area.
- Observation 6
Inadequate investigations and CAPA reviews
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, a. CAPA 15038, (b)(4), was issued for failed media fill Lot (b)(4) reported during the qualification of one employee for (b)(4) but failed to include a complete evaluation of machine parameters to ensure the reported failure was not associated to operating parameters and failed to include a comprehensive evaluation of impacted product (b)(4) with the same equipment. The investigation report describes that 5 unit vials (single dose droppers) were found leaking during the post-filling manual inspection, but no additional evaluation of the (b)(4) parameters was performed and the root cause was determined to be inadequate equipment use and maintenance. b. CAPA 15004, 1/15/15, was issued to describe the investigation of leaking units observed during the inspection of dispensed Vigamox 0.5% Lot VIG121714NUHM, Tetracaine Hydrochloride. The investigation describes the root cause as a (b)(4), but no additional information is included to determine the impact to other lots processed in the same machine or evaluate the qualification of the equipment for use. c. CAPA 16011, 4/13/16, was issued for the investigation of a failed potency test result (91% or close to the limit of [illegible]) for Brilliant Blue Lot BBL040416SVAB. No documented evidence was available with the CAPA report to describe the investigation process conducted on site prior to the release of the lot, which included a (b)(4) of the lot, laboratory investigation and re-analysis. d. CAPA 16019, 4/13/16, was issued for the investigation of a failed potency test result (117% or above specification of (b)(4)) for Vancomycin Lot VAN041216JHM. No documented evidence was available with the CAPA report to describe the investigation process conducted onsite prior to the release of the lot, which included a (b)(4) of the lot, laboratory investigation and re-analysis. e. Investigation reports for excursions in Environmental Monitoring (EM) samples (fingertips) collected during compounding operations were not fully documented or include timely and effective corrective/preventive actions. EM reports 10, 11, 13, 14, 26 issued during May-June 2015 failed to include a timely implementation of corrective and preventive actions, complete evidence for the identification of the microorganism, or evaluation of trend that would effectively prevent the recurrence of the events. All investigation reports describe out of limit results from 2-6 CFUs and describe the need to reinforce training to employees, without a timeframe for implementation to prevent recurrence. f. Complaint events identified on site as Quality Related Event Reports (QRE) as described in SOP 120.4, Corrective Action Preventive Action and Complaints, are not logged formally to ensure that all initial reports of events that could be evaluated as complaints are received and formally documented for evaluation. QREs include events reported by clients to the firm for evaluation and may include incorrect product fill/container, incorrect drug name, incorrect drug quantity or compound quality issues, among others.
- Observation 721 CFR 211
Supplier qualification and COA validation deficient
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals. Specifically, a. Certificates of Analysis received on site for non-sterile Bulk Drug Substances and evaluated in accordance with procedure 450.5, Receipt, Storage and Handling of Materials, are not reviewed to ensure the manufacturer is registered with FDA. b. Procedure 401.2, Vendor Qualification, approved for the qualification of vendors who supply active pharmaceutical ingredients, product components, and sample analysis for compounded products does not include a complete supplier qualification program. The procedure requires the (b)(4) for the qualification of a vendor, but does not require documented evidence of the information included with the (b)(4) (such as evidence for FDA registration and evidence of compliance with 21 CFR 211) or require an on-site audit at a regular frequency.
- Observation 8
Inadequate sterilization/depyrogenation procedures
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, a. SOP 324.2, Operation and Maintenance of (b)(4), used for glassware depyrogenation activities via validated (b)(4), does not define responsibilities and steps to be conducted for the execution of the (b)(4), intervention by (b)(4) described during this inspection, evaluation of the (b)(4) by the Quality Unit, documentation of (b)(4) obtained, and fails to include a timely review as the procedure requires a weekly review of executed (b)(4). b. SOP 322.3, Operation and Maintenance of (b)(4) used for sterilization of compounded product and materials used in routine operations via validated (b)(4) does not define responsibilities and steps to be conducted for the execution of the (b)(4), intervention by (b)(4) described during this inspection, evaluation of the (b)(4) (initially by operators) and the Quality Unit, and fails to include a timely review as the procedure requires a (b)(4) review of executed (b)(4).
- Observation 9
Stability testing/BUD program not followed
The written stability testing program is not followed. Specifically, your firm failed to follow SOP 890.1 "503B Beyond Use Dating" in that no stability studies or literature research was provided to support the 90-days or 6 months BUDs assigned to compounded injectable drug products and re-packaged ophthalmic drug products in single-use dose containers.
- Observation 10
Failure to report compounded products to FDA
Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the previous six months as required by section 503B(b)(2)(A). Specifically, the following products were compounded and not identified on your report dated 12/31/15: - Hydrocodone Bitartrate 10mg capsules - Lidocaine 40mg/ml / Epinephrine 0.5mg/ml / Tetracaine 5mg/ml 3 ml syringe - Promethazine 25mg/0.5 ml TD Gel 1 ml syringe - Butalbital 50mg/ml / Codeine 30mg/ml capsules - Vancomycin 250 mg/5ml 5ml syringe
- Observation 11
Missing required information on product labels
The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(B). Specifically, the following information is not found on your drug product labels: a) The statements "This is a compounded drug" and "Not for resale". Examples of product labels that do not contain this information: - Progesterone/Estradiol/Estriol/Testosterone 25mg/0.5mg/1.5mg/1mg/mL Cream in syringe - Progesterone/Estradiol/Estriol/Testosterone 60mg/0.5mg/0.5mg/0.5mg/mL Cream in syringe - Progesterone SL 10 mg tablets - DHEA (Dehydroepiandrosterone) 12 mg capsules b) The date the drug was compounded and list of active and inactive ingredients are not found on your product labels. Examples of drug product labels that do not contain this information include: - Progesterone/Estradiol/Estriol/Testosterone 25mg/0.5mg/1.5mg/1mg/mL Cream in syringe - Progesterone/Estradiol/Estriol/Testosterone 60mg/0.5mg/0.5mg/0.5mg/mL Cream in syringe - Progesterone SL 10 mg tablets - DHEA (Dehydroepiandrosterone) 12 mg capsules c) Furthermore, the following information is not found on the container labels for the drug products you produce: Information to facilitate adverse event reporting: www.fda.gov/medwatch and 1-800-FDA-1088. Examples of container labels that do not contain this information include: - Progesterone/Estradiol/Estriol/Testosterone 25mg/0.5mg/1.5mg/1mg/mL Cream in syringe - Progesterone/Estradiol/Estriol/Testosterone 60mg/0.5mg/0.5mg/0.5mg/mL Cream in syringe - Progesterone SL 10 mg tablets - DHEA (Dehydroepiandrosterone) 12 mg capsules
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Prepared for each batch, include complete information
Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Show 9 more citations
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Aseptic Processing Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
Calibration/Inspection/Checking not done
Routine calibration of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Written Procedures to Remove Pyrogens
There are no written standards or specifications, methods of testing, methods of cleaning, and methods of sterilization to remove pyrogenic properties.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features2 of 2
- 21 CFR 211.113Control of microbiological contamination2 of 2
- 21 CFR 211.166Stability testing2 of 2
- 21 CFR 211.192Production record review2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.28Personnel responsibilities1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
Show all 14
- 21 CFR 211.94Drug product containers and closures1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.167Special testing requirements1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3007271263 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3007271263. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.