Pennsylvania Correctional Industries
1100 Pike St, Huntingdon, Pennsylvania, United States
FEI 3007120595
FDA has one inspection on file for Pennsylvania Correctional Industries in Huntingdon, Pennsylvania (FEI 3007120595). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 28 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2012
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance28 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Prepared for each batch, include complete information
Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure.
Dedicated equipment: records part of batch record
The records of cleaning, maintenance, and use for dedicated equipment are not part of the batch record.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing, packaging, and holding of the drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Show 23 more citations
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Status of Each Lot Identified
Each lot of components, drug product containers, and closures was not appropriately identified as to its status in terms of being quarantined, approved or rejected.
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of rodenticides, insecticides, fungicides, fumigating agents, and cleaning and sanitizing agents designed to prevent the contamination of equipment, components, drug product containers, closures, packaging, labeling materials, and drug products.
Reporting of adverse drug experience to FDA
Written procedures describing the handling of all written and oral complaints do not include provisions for review to determine whether the complaint represents a serious and unexpected adverse drug experience which is required to be reported to the Food and Drug Administration.
Written procedures describing in detail
There is a lack of written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, examination, and testing of labeling and packaging materials.
Review of representative number of batches
Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Retention time of reserve samples, in general
Reserve samples for active ingredients and drug products are not retained for one year after the expiration date of the drug product.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Written warehousing procedures established/followed
Procedures describing the warehousing of drug products are not established.
Recall facilitation
A system by which the distribution of each lot of drug product can be readily determined to facilitate its recall if necessary, has not been established.
Calibration/Inspection/Checking not done
Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.
Written distribution procedure
Written distribution procedures are not established.
Supervisor Training/Education/Experience
Individuals responsible for supervising the manufacture, processing, packing, and holding of a drug product lack the education, training, and experience to perform their assigned functions in such a manner as to assure the drug product has the safety, identity, strength, quality and purity that it purports or is represented to possess.
Quality Control Review
Complaint procedures are deficient in that they do not include provisions that allow for the review and determination of an investigation by the quality control unit.
Procedures are written, and followed
Procedures designed to assure that correct labels, labeling, and packaging materials are used for drug products are not written.
GMP Training Frequency
GMP training is not conducted to assure that employees remain familiar with CGMP requirements applicable to them.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Test methods
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established.
Lack of quality control unit
There is no quality control unit.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.
Sampling and testing plans not described
Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.
Components withheld from use pending release
Each lot of components, drug product containers, and closures is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Regulations FDA cited here
The 22 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.56Sanitation1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.80General requirements1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
Show all 22
- 21 CFR 211.103Calculation of yield1 of 1
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 1
- 21 CFR 211.122Materials examination and usage criteria1 of 1
- 21 CFR 211.125Labeling issuance1 of 1
- 21 CFR 211.130Packaging and labeling operations1 of 1
- 21 CFR 211.142Warehousing procedures1 of 1
- 21 CFR 211.150Distribution procedures1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.170Reserve samples1 of 1
- 21 CFR 211.180General requirements1 of 1
- 21 CFR 211.182Equipment cleaning and use log1 of 1
- 21 CFR 211.186Master production and control records1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
- 21 CFR 211.198Complaint files1 of 1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3007120595 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3007120595. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.