Armstrong Pharmaceuticals, Inc.
25 John Rd, Canton, Massachusetts, United States
FEI 3007009553DUNS 809773794
FDA has 11 inspections on file for Armstrong Pharmaceuticals, Inc. in Canton, Massachusetts (FEI 3007009553), from 2008 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.192.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis, particle size reduction and distribution, through Dec 31, 2027. Its registrant is Armstrong Pharmaceuticals, Inc. (D-U-N-S 809773794).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 11, 2008–2026
- 0 OAI · 6 VAI · 5 NAI
- Inspections with 483 observations shown
- 4 of 11
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 2 requests, latest Jul 20, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
11 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch MonitoringCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Contamination, chemical or physical change, deterioration
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Acceptance/Rejection Levels
The statistical quality control criteria fail to include appropriate rejection levels.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Instruments, apparatus, et. al. not meeting specs
The use of instruments not meeting established specifications was observed.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Suitability of testing methods verified
The suitability of all testing methods is not verified under actual conditions of use.
Show 1 more citation
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch Monitoring8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function and written procedures required by current good manufacturing practice regulations.
Failure by applicant to report ADE
Adverse drug experience information has not been reported to FDA.
Interval
Periodic reports of non-alert adverse drug experiences have not been submitted yearly for an application which was approved three or more years ago.
Mix-up
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning an incident that caused a drug product or its labeling to be applied to another article.
Description of containers, labels, et. al.
Master production and control records lack a specimen or copy of each label and all other labeling and the signatures and dates entered by the person or persons responsible for the approval of labeling.
Show 3 more citations
Summary
An annual report did not include a brief summary of significant new information from the previous year that might affect the safety, effectiveness, or labeling of the drug product.
Failure to develop written procedures
Written procedures have not been developed for the surveillance, receipt, evaluation, and reporting to FDA of post marketing adverse drug experiences.
Timely submission
An annual report was not submitted within 60 days of the anniversary date of U.S. approval of the application to the FDA division responsible for reviewing the application.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 20, 2026. Each one asked for a Form 483.
Inspection ending May 8, 2026VAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 29, 2026. FDAgent holds no copy that FDA posted.
- Jul 20, 2026FDA-FOIA-2026-6890Form 483· 1 of 5 sitesRecords released
Inspection ending Jul 19, 2024VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 16, 2024FDA-FOIA-2024-9175Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 11 inspections, with how many of them cited each.
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 314.81Other postmarketing reports2 of 4
- 21 CFR 211.25Personnel qualifications1 of 4
- 21 CFR 211.63Equipment design, size, and location1 of 4
- 21 CFR 211.67Equipment cleaning and maintenance1 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 4
- 21 CFR 211.160General requirements1 of 4
- 21 CFR 211.165Testing and release for distribution1 of 4
Show all 11
- 21 CFR 211.186Master production and control records1 of 4
- 21 CFR 211.194Laboratory records1 of 4
- 21 CFR 314.80Postmarketing reporting of adverse drug experiences1 of 4
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, particle size reduction, distribution
- Registration runs through
- Dec 31, 2027
- Registrant
- Armstrong Pharmaceuticals, Inc.D-U-N-S 809773794
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3007009553 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3007009553. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.