Shair Laboratories, Inc.
1505 Portland Ave, Louisville, Kentucky, United States
FEI 3006899072DUNS 115965725
FDA has 3 inspections on file for Shair Laboratories, Inc. in Louisville, Kentucky (FEI 3006899072), from 2010 to 2011. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Feb 12, 2010. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
14 regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and labeling, through Dec 31, 2026. Its registrant is SHAIR LABORATORIES, INC. (D-U-N-S 115965725).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 3, 2010–2011
- 1 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Unapproved and Misbranded DrugsNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance27 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Consultant Records
Records are not maintained stating the consultant's qualifications.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing, and packaging of the drug product.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are not written or followed.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Show 22 more citations
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Defined areas of adequate size for operations
The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.
Labeling and packaging improperly approved/released
Labeling and packaging materials not meeting the appropriate written specifications were released for use.
Distinctive ID or code not recorded in batch record
The batch records do not record the distinctive identification number, code, and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
Distribution Recall System
The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.
Retention time of reserve samples, in general
Reserve samples for active ingredients and drug products are not retained for one year after the expiration date of the drug product.
Calibration - at intervals, written program, remedial action
The calibration of instruments, apparatus, and gauges is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of rodenticides, insecticides, fungicides, and fumigating agents designed to prevent the contamination of equipment, components, closures, packaging, labeling materials, and drug products.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Washing and toilet facilities are deficient
Washing and toilet facilities lack soap or detergent.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the sampling and testing of components, drug product containers, and closures.
In-process materials characteristics testing
In-process materials are not tested for identity, strength, quality, and purity and approved or rejected by the quality control unit during the production process.
Calibration/Inspection/Checking not done
Routine calibration of equipment is not performed according to a written program designed to assure proper performance.
Quarantine - actual practice
Drug products are not quarantined before being released by the quality control unit.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Lack of quality control unit
There is no quality control unit.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Sampling and testing plans not described
Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.
Representative samples after completion
Samples of representative units were not visually examined for correct labeling at the completion of finishing operations.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Unapproved and Misbranded Drugs15 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, and packing of a drug product lack the training required to perform their assigned functions.
Reserve samples identified, representative, stored
Reserve drug product samples are not retained and stored under conditions consistent with product labeling.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Lack of quality control unit
There is no quality control unit.
Show 10 more citations
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established, written, and followed.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Distinctive ID or code not recorded in batch record
The batch records do not record the distinctive identification number, code, and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.
Distribution Recall System
The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary.
In-process materials characteristics testing
In-process materials are not tested for identity, strength, quality, and purity and approved or rejected by the quality control unit during the production process.
Washing and toilet facilities are deficient
Washing and toilet facilities lack soap or detergent.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of rodenticides, insecticides, fungicides, and fumigating agents designed to prevent the contamination of equipment, components, drug product containers, closures, and drug products.
Regulations FDA cited here
The 24 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.25Personnel qualifications2 of 2
- 21 CFR 211.52Washing and toilet facilities2 of 2
- 21 CFR 211.56Sanitation2 of 2
- 21 CFR 211.67Equipment cleaning and maintenance2 of 2
- 21 CFR 211.80General requirements2 of 2
- 21 CFR 211.105Equipment identification2 of 2
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 2
Show all 24
- 21 CFR 211.125Labeling issuance2 of 2
- 21 CFR 211.137Expiration dating2 of 2
- 21 CFR 211.150Distribution procedures2 of 2
- 21 CFR 211.165Testing and release for distribution2 of 2
- 21 CFR 211.170Reserve samples2 of 2
- 21 CFR 211.198Complaint files2 of 2
- 21 CFR 211.34Consultants1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
- 21 CFR 211.103Calculation of yield1 of 2
- 21 CFR 211.111Time limitations on production1 of 2
- 21 CFR 211.122Materials examination and usage criteria1 of 2
- 21 CFR 211.134Drug product inspection1 of 2
- 21 CFR 211.142Warehousing procedures1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, labeling
- Registration runs through
- Dec 31, 2026
- Registrant
- SHAIR LABORATORIES, INC.D-U-N-S 115965725
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006899072 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006899072. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.