M W Laboratories Inc
2734 Ogeechee Rd, Savannah, Georgia, United States
FEI 3006394049
FDA has 3 inspections on file for M W Laboratories Inc in Savannah, Georgia (FEI 3006394049), from 2008 to 2011. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Dec 11, 2008. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 3, 2008–2011
- 1 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written distribution procedure
Written distribution procedures are not established.
Retention time of reserve samples, in general
Reserve samples for active ingredients and drug products are not retained for one year after the expiration date of the drug product.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Written warehousing procedures established/followed
Procedures describing the warehousing of drug products are not established.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and written.
Show 7 more citations
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Procedures Written and Followed
Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Lack of quality control unit
There is no quality control unit.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance25 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Adequate number of batches on stability
An adequate number of batches of each drug product are not tested nor are records of such data maintained to determine an appropriate expiration date.
Representative Samples
Representative samples are not taken of each shipment of each lot of components, drug product containers, and closures for testing or examination.
Description of containers and closures
Batch production and control records do not include a description of drug product containers used for each batch of drug product produced.
Written warehousing procedures established/followed
Procedures describing the warehousing of drug products are not established.
GMP Training Frequency
GMP training is not conducted on a continuing basis to assure that employees remain familiar with CGMP requirements applicable to them.
Show 20 more citations
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Procedures are written, and followed
Procedures designed to assure that correct labels, labeling, and packaging materials are used for drug products are not written.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are not written or followed.
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of rodenticides, insecticides, fungicides, fumigating agents, and cleaning and sanitizing agents designed to prevent the contamination of equipment, components, drug product containers, closures, packaging, labeling materials, and drug products.
Identity of major equipment and lines used
Batch production and control records do not include the identity of individual major equipment used for each batch of drug product produced.
Sampling and testing plans not described
Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.
Written procedures describing in detail
There is a lack of written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, examination, and testing of labeling and packaging materials.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing, control, instructions, sampling, testing, procedures, specifications, special notations, and precautions.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Specific information required in individual logs
Individual equipment logs do not show time, date, product, and lot number of each batch processed.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure.
Identification of each component or in-process material
Batch production and control records do not include the specific identification of each batch of component and in-process material used for each batch of drug product produced.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not free of infestation by rodents, birds insects, and other vermin.
Identification of persons involved, each significant step
Batch production and control records do not include the identification of the persons performing, directly supervising, and checking each significant step in the operation, for each batch of drug product produced.
Written distribution procedure
Written distribution procedures are not established.
Regulations FDA cited here
The 21 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.100Written procedures; deviations2 of 2
- 21 CFR 211.142Warehousing procedures2 of 2
- 21 CFR 211.150Distribution procedures2 of 2
- 21 CFR 211.165Testing and release for distribution2 of 2
- 21 CFR 211.166Stability testing2 of 2
- 21 CFR 211.188Batch production and control records2 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
Show all 21
- 21 CFR 211.56Sanitation1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.80General requirements1 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.122Materials examination and usage criteria1 of 2
- 21 CFR 211.125Labeling issuance1 of 2
- 21 CFR 211.130Packaging and labeling operations1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.170Reserve samples1 of 2
- 21 CFR 211.182Equipment cleaning and use log1 of 2
- 21 CFR 211.186Master production and control records1 of 2
- 21 CFR 211.198Complaint files1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006394049 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006394049. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.