Skip to content

M W Laboratories Inc

2734 Ogeechee Rd, Savannah, Georgia, United States

FEI 3006394049

FDA has 3 inspections on file for M W Laboratories Inc in Savannah, Georgia (FEI 3006394049), from 2008 to 2011. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

The most recent OAI inspection ended on Dec 11, 2008. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
3, 2008–2011
1 OAI · 1 VAI · 1 NAI
Inspections with 483 observations shown
2 of 3
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written distribution procedure

      Written distribution procedures are not established.

    2. Retention time of reserve samples, in general

      Reserve samples for active ingredients and drug products are not retained for one year after the expiration date of the drug product.

    3. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    4. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not established.

    5. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and written.

    Show 7 more citations
    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    2. Procedures Written and Followed

      Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written.

    3. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    4. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    5. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    6. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    7. Lack of quality control unit

      There is no quality control unit.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance25 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested nor are records of such data maintained to determine an appropriate expiration date.

    2. Representative Samples

      Representative samples are not taken of each shipment of each lot of components, drug product containers, and closures for testing or examination.

    3. Description of containers and closures

      Batch production and control records do not include a description of drug product containers used for each batch of drug product produced.

    4. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not established.

    5. GMP Training Frequency

      GMP training is not conducted on a continuing basis to assure that employees remain familiar with CGMP requirements applicable to them.

    Show 20 more citations
    1. Calibration - at intervals, written program, remedial action

      The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.

    2. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    3. Procedures are written, and followed

      Procedures designed to assure that correct labels, labeling, and packaging materials are used for drug products are not written.

    4. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are not written or followed.

    5. Written procedures lacking for use of pesticides etc.

      Written procedures are lacking for the use of rodenticides, insecticides, fungicides, fumigating agents, and cleaning and sanitizing agents designed to prevent the contamination of equipment, components, drug product containers, closures, packaging, labeling materials, and drug products.

    6. Identity of major equipment and lines used

      Batch production and control records do not include the identity of individual major equipment used for each batch of drug product produced.

    7. Sampling and testing plans not described

      Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.

    8. Written procedures describing in detail

      There is a lack of written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, examination, and testing of labeling and packaging materials.

    9. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.

    10. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    11. Manufacturing Instructions and Specifications

      The master production and control records are deficient in that they do not include complete manufacturing, control, instructions, sampling, testing, procedures, specifications, special notations, and precautions.

    12. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    13. Specific information required in individual logs

      Individual equipment logs do not show time, date, product, and lot number of each batch processed.

    14. Written records kept in individual logs

      Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.

    15. Written procedures followed

      Procedures for the preparation of master production and control records are not described in a written procedure.

    16. Identification of each component or in-process material

      Batch production and control records do not include the specific identification of each batch of component and in-process material used for each batch of drug product produced.

    17. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    18. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not free of infestation by rodents, birds insects, and other vermin.

    19. Identification of persons involved, each significant step

      Batch production and control records do not include the identification of the persons performing, directly supervising, and checking each significant step in the operation, for each batch of drug product produced.

    20. Written distribution procedure

      Written distribution procedures are not established.

Regulations FDA cited here

The 21 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

Show all 21

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006394049 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006394049. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.