Skip to content

Hanlim Pharm Co. Ltd.

Hallimjeyakjungangyeonguso, 2-27 Yeongmun-Ro; Cheoin, Yongin, Gyeonggi-do, Korea (the Republic of)

FEI 3004886113DUNS 687986034

FDA has 6 inspections on file for Hanlim Pharm Co. Ltd. in Yongin, Gyeonggi-do (FEI 3004886113), from 2014 to 2026. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 11 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three of the five FOIA requests for this site have asked FDA for this inspection's 483.

2 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.

Six regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and labeling, through Dec 31, 2027. Its registrant is Hanlim Pharm. Co., Ltd. (D-U-N-S 687986034).

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
6, 2014–2026
2 OAI · 3 VAI · 1 NAI
Inspections with 483 observations shown
4 of 6
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
5 requests, latest Aug 12, 2026
Warning letters
· CDER ↗
2 on file
Import refusals
2 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    2. Results not used for expiration dates, storage cond.

      Results of stability testing are not used in determining expiration dates.

    3. Defined areas of adequate size for operations

      The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.

    4. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    5. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    Show 6 more citations
    1. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    3. Following/documenting laboratory controls

      Established test procedures are not documented at the time of performance.

    4. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    6. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  2. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. input/output verification

      Input to and output from the computer and records or data are not checked for accuracy.

    2. Backup file not maintained

      Failure to maintain a backup file of data entered into the computer or related system. Electronic records are used, but they do not meet audit trail requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.

  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

    2. Training , Education , Experience overall

      Employees engaged in the processing of a drug product lack the training required to perform their assigned functions.

    3. Following/documenting laboratory controls

      Established test procedures are not documented at the time of performance.

    4. Backup data not assured as exact and complete

      Backup data is not assured as secure from alteration, erasure or loss through keeping hard copy or alternate systems.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    Show 2 more citations
    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. GMP Training Frequency

      GMP training is not conducted with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.

    2. Component Name and Code

      The master production and control records are deficient in that they do not include a complete list of components designated by name and code sufficiently specific to indicate any special characteristic.

    3. Aseptic Processing Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    5. Cleaning/maintenance records not kept

      Records are not kept for the maintenance, cleaning, sanitizing, and inspection of equipment.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on Aug 12, 2026. Each one asked for a Form 483.

  • Inspection ending Apr 24, 2026OAI

    3 requests. In the inspection history above. FDA has posted its Form 483.

    1. Aug 12, 2026FDA-FOIA-2026-7750Form 483· 1 of 3 sitesRecords released
    2. Jul 31, 2026FDA-FOIA-2026-7333Form 483Records released
    3. Jul 23, 2026FDA-FOIA-2026-7096Form 483· 1 of 2 sitesRecords released
  • Inspection date not given

    2 requests. FDA released records in answer to a request for its Form 483 + EIR on Jul 10, 2025. FDAgent holds no copy that FDA posted.

    1. May 28, 2025FDA-FOIA-2025-7082Form 483 + EIRRecords released
    2. Feb 4, 2025FDA-FOIA-2025-991Form 483 + EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 10 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 6 inspections, with how many of them cited each.

Show all 10

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004886113, one row per refused product line.

2 refusals on 2018-06-13 · charged DRUG GMPS on 2 · no FDA sample analysis

FDA firm profile
  • 2018-06-13

    WATER, PURIFIED (EYEWASH)65FBK06

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of West Coast ImportsEPM-0144197-7/11/2

  • 2018-06-13

    WATER, PURIFIED (EYEWASH)65FBK06

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of West Coast ImportsEPM-0144197-7/11/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling
Registration runs through
Dec 31, 2027
Registrant
Hanlim Pharm. Co., Ltd.D-U-N-S 687986034

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004886113 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004886113. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.