FDA has 3 inspections on file for Future Foam, Inc. in San Clemente, California (FEI 3004758248), from 2015 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published 8 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Jan 13, 2023. 8 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.170(b) and 21 CFR 211.63.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and packing, through Dec 31, 2026. Its registrant is Future Foam, Inc. (D-U-N-S 007261415).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2015–2024
1 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
2 of 3
Form 483s posted by FDA
↗
Requested under FOIA
3 requests, latest FY2023
Warning letters
None on file
Import refusals
8 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    2. In-process materials specifications

      In-process specifications are not derived from previous acceptable process average and process variability estimates where possible.

    3. Drug product reserve containers

      Drug product reserve samples are not stored in the same immediate container-closure system as the marketed product and an immediate container-closure system that has essentially the same characteristics as the marketed product.

    4. Individual inventory record

      Records fail to include an individual inventory record of each component and reconciliation of the use of each component with sufficient information to allow determination of any associated batch or lot of drug product.

    5. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    Show 3 more citations
    1. Personnel dating/signing equipment log

      The persons performing and double-checking the cleaning and maintenance are not dating and signing or initialing the equipment cleaning and use log.

    2. Representative Samples Criteria

      The number of containers to be sampled and amount of material taken from each container is not based upon appropriate criteria.

    3. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written program not followed

      The written stability testing program is not followed.

    2. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    3. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    4. Items to cover on annual reviews

      Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.

    5. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use.

    Show 4 more citations
    1. Annual visual exams of drug products

      Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.

    2. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    3. Rejecting When Specifications Not Met

      Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.

    4. Quality control unit review of records

      Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending Sep 27, 2024VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jun 29, 2026FDA-FOIA-2026-6177Form 483· 1 of 4 sitesRecords released
  • Inspection ending Jan 13, 2023OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-4136Form 483Closed
  • Inspection ending Oct 18, 2021

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Jul 6, 2022FDA-FOIA-2022-4866Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 13 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

Show all 13

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004758248, one row per refused product line.

8 refusals on 2026-03-05 · charged FRNMFGREG on 8, 9999978 on 8 · no FDA sample analysis

FDA firm profile
  • 2026-03-05

    ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBJ18

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Charge 9999978

    Division of Southwest Imports218-7287670-7/1430001/4

  • 2026-03-05

    ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBJ18

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Charge 9999978

    Division of Southwest Imports218-7287670-7/1430001/3

  • 2026-03-05

    ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBJ18

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Charge 9999978

    Division of Southwest Imports218-7287670-7/1430001/2

  • 2026-03-05

    ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBJ18

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Charge 9999978

    Division of Southwest Imports218-7287670-7/1430001/1

  • 2026-03-05

    ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBJ18

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Charge 9999978

    Division of Southwest Imports218-7287665-7/710001/4

Show 3 more
  • 2026-03-05

    ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBJ18

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Charge 9999978

    Division of Southwest Imports218-7287665-7/710001/3

  • 2026-03-05

    ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBJ18

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Charge 9999978

    Division of Southwest Imports218-7287665-7/710001/2

  • 2026-03-05

    ZINC OXIDE (ULTRAVIOLET SCREEN/SUNSCREEN)66PBJ18

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Charge 9999978

    Division of Southwest Imports218-7287665-7/710001/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing
Registration runs through
Dec 31, 2026
Registrant
Future Foam, Inc.D-U-N-S 007261415

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004758248 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004758248. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.