Packagina On Demand, Inc. Form 483, September 2024
FDA issued this Form 483 to Packagina On Demand, Inc. in San Clemente, California (FEI 3004758248) at the end of a drug inspection that ended September 27, 2024. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 27, 2024
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 13, 2026
- 777 days after the inspection
FDA's 8 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
In-process materials specifications
In-process specifications are not derived from previous acceptable process average and process variability estimates where possible.
Drug product reserve containers
Drug product reserve samples are not stored in the same immediate container-closure system as the marketed product and an immediate container-closure system that has essentially the same characteristics as the marketed product.
Individual inventory record
Records fail to include an individual inventory record of each component and reconciliation of the use of each component with sufficient information to allow determination of any associated batch or lot of drug product.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Personnel dating/signing equipment log
The persons performing and double-checking the cleaning and maintenance are not dating and signing or initialing the equipment cleaning and use log.
Representative Samples Criteria
The number of containers to be sampled and amount of material taken from each container is not based upon appropriate criteria.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.