Skip to content

Miramar Cosmetics, Inc

2301 Nw 107th Ave Ste 101, Doral, Florida, United States

FEI 3004486512DUNS 012873243

Company: Miramar Lab · Linked by exact D-U-N-S match (012873243) in FDA registration data

FDA has 4 inspections on file for Miramar Cosmetics, Inc in Doral, Florida (FEI 3004486512), from 2011 to 2024. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One FOIA request has asked FDA for this inspection's 483.

FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Three regulations were cited at more than one inspection: 21 CFR 211.22(d), 21 CFR 211.25(a) and 21 CFR 211.63.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is Miramar Cosmetics, Inc DBA Miramar Lab (D-U-N-S 012873243).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
4, 2011–2024
2 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
3 of 4
1 with citations published, text not held
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
1 request, latest Sep 10, 2024
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    2. Written procedures not established/followed

      Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    4. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use and cleaning and maintenance.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Unapproved and Misbranded DrugsCitations published; text not held
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Unapproved and Misbranded Drugs18 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written Procedures Not Followed

      Written procedures are not followed for the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.

    2. Quality control unit review of records

      Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

    3. Cleaning/maintenance records not kept

      Records are not kept for the maintenance, cleaning, sanitizing, and inspection of equipment.

    4. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    5. Training , Education , Experience overall

      Employees engaged in the manufacture, processing, packing, and holding of a drug product lack the education, training, and experience required to perform their assigned functions.

    Show 13 more citations
    1. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

    2. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    3. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    4. Identification of new containers

      For components removed from the original containers, the new container fails to be identified with component name or item code, receiving or control number, weight or measure, and batch for which component was dispensed including product name, strength and lot number.

    5. Individual inventory record

      Records fail to include an individual inventory record of each component, reconciliation of the use of each component, drug product container, and drug product closure with sufficient information to allow determination of any associated batch or lot of drug product.

    6. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    7. Batch production and Batch Control Record Requirements

      The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, packing, and holding.

    8. Examination of packaging and labeling

      Examination of packaging and labeling materials for suitability and correctness before packaging operations is not performed and not documented in the batch production records.

    9. Written calibration / inspection records not kept

      Records of the calibration checks and inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.

    10. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written, and followed.

    11. Adequate space lacking to prevent mix-ups and contamination

      The building lacks adequate space for the orderly placement of equipment and materials to prevent mix-ups between different components, drug product containers, closures, labeling, in-process materials, and drug products and to prevent contamination.

    12. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    13. Review of representative number of batches

      Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Sep 10, 2024. It asked for a Form 483.

  • Inspection ending Feb 23, 2024OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Sep 10, 2024FDA-FOIA-2024-8085Form 483· 1 of 5 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 18 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.

Show all 18

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2026
Registrant
Miramar Cosmetics, Inc DBA Miramar LabD-U-N-S 012873243

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004486512 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004486512. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.