Intas Pharmaceuticals Limited
Pharmez Plot No 5-14, Near Village Matoda; Sarkhej-Bavla Highway No 8-A, Sanand, India
FEI 3004011473DUNS 915837971
Company: Intas Pharmaceuticals Limited · Linked by exact D-U-N-S match (725927649) in FDA registration data
FDA has 7 inspections on file for Intas Pharmaceuticals Limited in Sanand, India (FEI 3004011473), from 2011 to 2022. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 11 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two FOIA requests have asked FDA for this inspection's records.
14 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.113(b).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, Intas Pharmaceuticals Limited (D-U-N-S 725927649), has registered 2 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 7, 2011–2022
- 1 OAI · 4 VAI · 2 NAI
- Inspections with 483 observations shown
- 2 of 7
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 2 requests, latest FY2023
- Warning letters
- · CDER ↗
- Import refusals
- 14 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Extent of discrepancy, failure investigations
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other drug products that may have been associated with the specific failure or discrepancy.
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Following/documenting laboratory controls
Established test procedures and laboratory control mechanisms are not followed.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Show 6 more citations
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
Results not used for expiration dates, storage cond.
Results of stability testing are not used in determining.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training , Education , Experience overall
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions.
Calibration/Inspection/Checking not done
Routine checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.
Inspection ending Dec 2, 2022OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- FY2023FDA-FOIA-2023-2386Inspection recordsWithdrawn
- FY2023FDA-FOIA-2022-8594Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 2
- 21 CFR 211.113Control of microbiological contamination2 of 2
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
Show all 11
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.192Production record review1 of 2
- 21 CFR 211.194Laboratory records1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004011473, one row per refused product line.
14 refusals from 2020-07-27 to 2026-08-25 · charged DRUG GMPS on 8, UNAPPROVED on 8 · no FDA sample analysis
FDA firm profile- 2026-08-25
MIRTAZAPINE (ANTI-DEPRESSANT)61NDA73
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsAEK-9615283-8/30002/1
- 2026-04-17
MINOXIDIL (ANTI-HYPERTENSIVE)62CCY41
NOT LISTED 502(o), 801(a)(3); MISBRANDING
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-0162570-5/40002/1
- 2025-08-27
ACETAMINOPHEN (ANALGESIC)60LDA01
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast Imports799-0516804-5/30002/1
- 2025-08-20
MISCELLANEOUS PATENT MEDICINES, ETC.66VCY99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast ImportsKH5-4157161-9/20002/1
- 2025-08-18
CLOPIDOGREL BISULFATE (ANTI-COAGULANT)61LDE38
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast ImportsAEK-7457773-3/20002/1
Show 9 more
- 2025-07-11
ANALGESIC, N.E.C.60LIY99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-7231304-0/12/1
- 2025-07-03
ESCITALOPRAM OXALATE61NDY83
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-7262024-6/12/1
- 2025-06-30
MISCELLANEOUS PATENT MEDICINES, ETC.66VDY99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsAEK-7265900-4/62/1
- 2025-01-17
GEMCITABINE HCL (ANTI-NEOPLASTIC)62IIY80
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports231-4226207-7/11/1
- 2023-07-28
OFLOXACIN (ANTI-BACTERIAL, PART II) (NOT ANTIBIOTIC)61GDY85
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-6023796-4/11/2
- 2022-10-28
MINOXIDIL (ANTI-HYPERTENSIVE)62CCY41
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-1166470-4/11/1
- 2021-05-10
PROGESTERONE (PROGESTIN)65JDY31
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-5221302-4/11/1
- 2021-03-02
ANGIOTENSIN AMIDE (VASOCONSTRICTOR)66RDA01
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-4248193-9/11/17
- 2020-07-27
METOPROLOL SUCCINATE (ANTI-HYPERTENSIVE - PART II)62ODY43
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-7630985-2/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Intas Pharmaceuticals LimitedD-U-N-S 725927649
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Intas Pharmaceuticals Limited (D-U-N-S 725927649) as the registrant for this site and the 2 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Intas Pharmaceuticals LimitedAhmedabad, India · FEI 300315749811 inspections11latestJul 12, 2024NAI1 warning letter, Nov 21, 2023
- Intas Pharmaceuticals LimitedGujarat, India · FEI 3007277149Registered; no FDA inspection on file
Other FEIs recorded as Intas Pharmaceuticals Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Intas Pharmaceuticals LimitedFEI 3011743992Bharuch, India
Last inspected 2016-03-17VAI
Intas Pharmaceuticals LimitedFEI 3005354974Ahmedabad, India
Last inspected 2015-04-03VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3004011473 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3004011473. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.