Zep Inc
350 Joe Frank Harris Pkwy, Emerson, Georgia, United States
FEI 3003906462DUNS 112125310
FDA has 5 inspections on file for Zep Inc in Emerson, Georgia (FEI 3003906462), from 2009 to 2024. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
10 regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is Zep Inc. (D-U-N-S 030471374).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 5, 2009–2024
- 1 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 4 of 5
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 2 requests, latest Aug 28, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls and returned or salvaged drug products.
Adequate number of batches on stability
An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Test methods
The accuracy, sensitivity and specificity of test methods have not been established.
Show 7 more citations
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are not written or followed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program.
Quarantine Storage of Components
Incoming components, drug product containers, and closures are not stored under quarantine until they have been tested or examined, as appropriate, and released.
Label storage access limited to authorized personnel
Access to the storage area for labels and labeling materials is not limited to authorized personnel.
Testing in same container - closure system
The written stability program does not assure testing of the drug product in the same container-closure system as that in which the drug product is marketed.
Written procedures describing in detail
There is a lack of written procedures describing in sufficient detail the receipt, identification, and storage of labeling and packaging materials.
Show 4 more citations
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of insecticides designed to prevent the contamination of packaging, labeling materials and drug products.
Quarantine - actual practice
Drug products are not quarantined before being released by the quality control unit.
Written warehousing procedures established/followed
Procedures describing the warehousing of drug products are not established.
Drug product reserve containers
Drug product reserve samples are not stored in the same immediate container-closure system as the marketed product and an immediate container-closure system that has essentially the same characteristics as the marketed product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance17 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, returned or salvaged drug products, and investigations conducted for each drug product.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and completeness.
Test method modification records not maintained
Complete records are not maintained of any modification of an established method employed in testing.
Reprocessing procedures lack steps to be taken
Reprocessing procedures lack the steps to be taken to insure that reprocessed batches will conform with all established standards, specifications, and characteristics.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Show 12 more citations
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Test methods
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification as a condition for their approval and release.
Component addition checked by 2nd person
Each component is not added to a batch by one person and verified by a second person.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are not written or followed.
Valid stability test methods
The written stability program for drug products does not include reliable, meaningful, and specific test methods.
Adequate number of batches on stability
An adequate number of batches of each drug product are not tested nor are records of such data maintained to determine an appropriate expiration date.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Testing in same container - closure system
The written stability program does not assure testing of the drug product in the same container-closure system as that in which the drug product is marketed.
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Aug 28, 2025. Each one asked for a Form 483.
Inspection ending Oct 24, 2024OAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 12, 2025. FDAgent holds no copy that FDA posted.
- Aug 28, 2025FDA-FOIA-2025-10328Form 483Records released
- Jan 28, 2025FDA-FOIA-2025-796Form 483· 1 of 3 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 21 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.166Stability testing3 of 4
- 21 CFR 211.170Reserve samples3 of 4
- 21 CFR 211.25Personnel qualifications2 of 4
- 21 CFR 211.67Equipment cleaning and maintenance2 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 4
- 21 CFR 211.160General requirements2 of 4
- 21 CFR 211.165Testing and release for distribution2 of 4
- 21 CFR 211.180General requirements2 of 4
Show all 21
- 21 CFR 211.198Complaint files2 of 4
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
- 21 CFR 211.56Sanitation1 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 4
- 21 CFR 211.82Receipt and storage of untested components, drug product containers, and closures1 of 4
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 4
- 21 CFR 211.100Written procedures; deviations1 of 4
- 21 CFR 211.101Charge-in of components1 of 4
- 21 CFR 211.115Reprocessing1 of 4
- 21 CFR 211.122Materials examination and usage criteria1 of 4
- 21 CFR 211.142Warehousing procedures1 of 4
- 21 CFR 211.192Production record review1 of 4
- 21 CFR 211.194Laboratory records1 of 4
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- Zep Inc.D-U-N-S 030471374
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003906462 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003906462. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.