Emerald 3 Enterprises, Inc.
725 W US Hwy 54, PO Box 3047, Camdenton, Missouri, United States
FEI 3003314670
FDA has 3 inspections on file for Emerald 3 Enterprises, Inc. in Camdenton, Missouri (FEI 3003314670), from 2011 to 2013. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 2 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
10 regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2011–2013
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Stability sample storage conditions described
The written stability program for drug products does not describe the storage conditions for samples retained for testing.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Calibration/Inspection/Checking not done
Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.
Deviations of production time limits
Deviations from production time limits are not justified.
Show 7 more citations
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Written program not followed
The written stability testing program is not followed.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance.
Sampling and testing plans not described
Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing and packaging of the drug product.
Dates not included for each significant step
Batch production and control records do not include dates of each significant step in the manufacture, processing, packing, and holding of the batch for each batch of drug product produced.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance20 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release.
Dates not included for each significant step
Batch production and control records do not include dates of each significant step in the manufacture, processing, packing, and holding of the batch for each batch of drug product produced.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Components withheld from use pending release
Each lot of components and drug product containers is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.
Show 15 more citations
Sampling and testing plans not described
Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of insecticides designed to prevent the contamination of equipment, components, drug product containers, packaging, labeling materials, and drug products.
Yield calculations not verified by 2nd person
Yield calculations are not performed by one person and independently verified by a second person.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written, and followed.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include assignment of responsibility, description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance, and instructions for protection of clean equipment from contamination prior to use.
Procedures Written and Followed
Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established.
Lack of quality control unit
There is no quality control unit.
Quarantine of Rejected Components et. al.
Rejected drug product containers are not controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Regulations FDA cited here
The 19 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures3 of 3
- 21 CFR 211.166Stability testing3 of 3
- 21 CFR 211.25Personnel qualifications2 of 3
- 21 CFR 211.67Equipment cleaning and maintenance2 of 3
- 21 CFR 211.100Written procedures; deviations2 of 3
- 21 CFR 211.103Calculation of yield2 of 3
- 21 CFR 211.111Time limitations on production2 of 3
- 21 CFR 211.165Testing and release for distribution2 of 3
Show all 19
- 21 CFR 211.188Batch production and control records2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.56Sanitation1 of 3
- 21 CFR 211.63Equipment design, size, and location1 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.89Rejected components, drug product containers, and closures1 of 3
- 21 CFR 211.113Control of microbiological contamination1 of 3
- 21 CFR 211.125Labeling issuance1 of 3
- 21 CFR 211.160General requirements1 of 3
- 21 CFR 211.198Complaint files1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003314670 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003314670. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.