Ampharmco LLC
1401 Joel East Rd, Fort Worth, Texas, United States
FEI 3002668504DUNS 038023805
FDA has 8 inspections on file for Ampharmco LLC in Fort Worth, Texas (FEI 3002668504), from 2010 to 2025. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis, relabeling and repacking, through Dec 31, 2027. Its registrant is Ampharmco, LLC (D-U-N-S 038023805).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 8, 2010–2025
- 0 OAI · 3 VAI · 5 NAI
- Inspections with 483 observations shown
- 3 of 8
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food Additives2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.
Cleaning SOPs/instructions
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Adequate space lacking to prevent mix-ups and contamination
The building lacks adequate space for the orderly placement of equipment and materials to prevent mix-ups between different components, drug product containers, in-process materials and drug products and to prevent contamination.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calculated Excess of Components Used
The master production and control records are deficient in that they do not include a statement concerning any calculated excess of component.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Testing Each Component for Conformity with Specs
Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
Show 3 more citations
Review of representative number of batches
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of cleaning and sanitizing agents designed to prevent the contamination of equipment, components, drug product containers, closures, and drug products.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 8 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance2 of 3
- 21 CFR 211.42Design and construction features1 of 3
- 21 CFR 211.56Sanitation1 of 3
- 21 CFR 211.63Equipment design, size, and location1 of 3
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.113Control of microbiological contamination1 of 3
Show all 12
- 21 CFR 211.160General requirements1 of 3
- 21 CFR 211.180General requirements1 of 3
- 21 CFR 211.186Master production and control records1 of 3
- 21 CFR 211.192Production record review1 of 3
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, relabeling, repacking
- Registration runs through
- Dec 31, 2027
- Registrant
- Ampharmco, LLCD-U-N-S 038023805
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002668504 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002668504. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.