Jubilant HollisterStier General Partnership
16751 Rte Transcanadienne, Kirkland, Canada
FEI 3001623073DUNS 246762764
FDA has 10 inspections on file for Jubilant HollisterStier General Partnership in Kirkland, Canada (FEI 3001623073), from 2009 to 2025. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 9 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two of the 10 FOIA requests for this site have asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.113(b), 21 CFR 211.160(b) and 21 CFR 211.22(d).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is Jubilant HollisterStier General Partnership (D-U-N-S 246762764).
Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 10, 2009–2025
- 4 OAI · 3 VAI · 3 NAI
- Inspections with 483 observations shown
- 5 of 10
- Requested under FOIA
- 10 requests, latest FY2023
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing and processing.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Show 4 more citations
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 15 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate statistical quality controls
OBSERVATION 1 The statistical quality control criteria fail to include appropriate acceptance levels and rejection levels. A. Your firm failed to perform an adequate evaluation for (b) 4 (b)( ) Expiration Date July 2025, and partially released t For example: 4 4 4 1. You filled 6J<1--i1ot(b}<> fro (b)<> non-viable particle (NV alert and action limit alarms were detected through your Particle Measurement System (PMS) for particles ~~> μm. Your firm reviewed the alarms as part during batch review for release you reviewed the PMS data report, which not only showed alert and action limit excursions for particles~(~ μm but also showed alert and action limits were exceeded for particles [~ μm. However, you failed to identify these alarms during review sampling reports were reviewed by production and approved on February 20, 2024. 2. On March 05, 2024, during a batch retrospective review, you found (b)l exceeding both alert and action level limits for particles time of filling. Investigation PR230970 was opened you identified two (2) events where particles exceeded action limits for inadequate because your PMS NVP data report showed there were approximately 36 action level excursions during the filling defined in your investigation. Furthermore, your corrective action (CAPA) was 6 4 product (i.e., basketsl ><> for this lot. However, your investigation lacks suppo 3. On March 11, 2024, you opened Investigation 4 inspection showing a result of 6J (43/od(b) <>, units out investigation you state there was a compromised seal cause was due to an equipment malfunctioning issue. Nonetheless, 4 4 is no impact to ~6)<> )ot[{b)<> 1ecause 100% visual inspection was carried out and because your AQL was conforming. However, your investigation states there are no established reject limits for your product, including reject limits for critical defects. Furthermore, during review your firm had completed over 1 <b)<4f ] units of for 100% visual inspection. Repeat Observation (B) Your visual inspection program is deficient in 6 4 testing in your < ><> sterile products (i.e., topical solutions and ointment) and inspection of your b)<4> sterile ointment products. Although your firm has initiated supplemental 6 4 destructive testing in your sterile (b)<> products and begun 100% visual inspection for your ~ ointments, your tests are currently for informational purposes. You stated that t6)l'l)7 batches for each product; however, according to your Quality Director, it may take approximately ~ year to complete your destructive testing assessment for topical solutions and up your destructive testing and 100% visual inspection assessment for your topical ointments. Repeat Observation
- Observation 2
Insufficient QCU and EM investigations
OBSERVATION 2 There is a failure to thoroughly review any unexplained discrepancy components to meet any of its specifications whether Specifically, A. Your Quality Control Unit (QCU) did not conduct a thorough evaluation and implement appropriate and effective corrective actions in a timely manner for alarms observed in your Nonviable Particle Measuring System located in your aseptic fill area. From November were inaccurately assessed in at least [~~ batches due to incorrect limits set ~ batches13 had critical alarms exceeding alert and action limits that were not identified for particles ~ ~ μm. Your firm investigated as part of PR 230695 and attributed this discrepancy as incorrect limits being placed in your Particle Measuring System (PMS). However, your firm failed to carry out a comprehensive assessment of your alarm review process to establish act within production and quality oversight. 1. You do not evaluate the complete nonviable particulate data reports for all the batches you manufacture in your aseptic processing rooms. Your firm release; however, you only review the complete nonviable particulate data reports if the summaries show alert and action limits are exceeded during batch production. 2. Your firm does not perform a verification check to ensure the limits for the particle counter system are accurate prior to production in your aseptic processing rooms. B. Environmental Monitoring investigations for deficient. 1. Investigation PR 234186 was opened on April sample taken on ar<fi)<> _J in the (bf<. The following deficiencies were noted: a. Your investigation does not define the actions taken in the area such as cleaning. There is no documentation as was performed for the room following this excursion. b. Your firm does not document the locations where (b) in the area. According to Working Instructions JHSM- Apr 30, 2024, Sampling Plan(b)<>, sampling of ~b)<4> in the l document the (b)<> rl~c resample was taken on at the same location as your initial sample that resulted in the action limit excursion. 2. Investigation PR 223437 was opened on December 21, 2023, for an action-level result of personnjJ monitntin 2-(finiatet;..dabs) for an environmental monitoring quality inspector during the filling setup odb)<> (b)(4,15-iL assessment and determined the organism. Your firm rejected this batch. Your investigation is deficient in that, although your firm rejected the batch, you failed to establish the overall impact this excursion had to your Grade A area. You did not define the actions taken or provide evidence showing to ensure a high-risk organism does not affect your aseptic processing core.
Show observations 3 to 15
- Observation 3
Inadequate segregation and flow controls
OBSERVATION 3 Separate or defined areas to prevent contamination to aseptic processing of drug products. A. There is no assurance that the current flow of designed to prevent microbial contamination in the aseptic core. Your current procedures require personnel to leave the aseptic processing room and its critical areas and travel through the shared corridors to perform activities during manufacturing operation. For example: 1. JHSM-SOP-2003INS17, Revision [..], "Gown and Gloves Monitoring" requires (b) (4) (b) (4) Your aseptic area is not designed with methods to prevent operators from the aseptic processing rooms. In addition, operators can remain in the corridors (b) (4) the aseptic processing rooms. 2. JHSM-SOP-1072, Revision 20, effective date Nov 15, 2023, procedure for "Good Manufacturing Practices... and Gowning Procedure for the Aseptic Zones" requires (b) <> ~ 4 To change, (b) <> u, lpersonnel m11 enter the shared corridors to their (b) <> working in different rooms cross paths in the corridors. Moreover, your firm does not record the number of times operators leave the aseptic processing rooms to change their damaged f. 3. JHSM-SOP-1072, Revision 20, effective date Nov 15, 2023, procedure for "Good Manufacturing Practices and Gowning Procedure for the Aseptic Zones" requires (b)(4) aseptic area is documented, you do not document the reasons for exit including aseptic area due to (6)(-l} issues. 4. The distance between the fill rooms to the (b) < below: Aseptic Processing Room Room # 6)(4) B. Differential pressure is not being monitored in the firm only monitors the Grade B room differential pressure and the adjacent 4 monitor differential pressure for your (b) l > not established a system to continuously monitor positive differential pressure is continuously maintained during F C. The design of your f(bH >) line located in Filling throughout the Grade A/B areas do not provide adequate protection, separation, and controls to prevent the risk of contamination of your aseptically filled sterile drug products. For example, the distance of the HMIs and the conveyor in (bf(.ilJ The current design of the (b)(.ii) line does not prevent potential contamination originating from the HMI panels themselves, since any particles emitted by the panels could compromise the cleanliness. Each time a process parameter is monitored or aseptic core of the <6J<4> line.
- Observation 4
Inadequate media fill and smoke studies
OBSERVATION 4 Procedures designed to prevent microbiological contamination did not include adequate validation of the aseptic process. A. The aseptic process simulations (media fills) performed in commercial aseptic filling process. Specifically, 1. Operators do not record or document in your commercial batch records routine corrective interventions such interventions have a duration of ~b)(<) filling line stops. Additionally, none of the monitoring of the commercial filling are documented in the commercial batch records. Therefore, there is no assurance that the frequency at which such interventions are simulated during aseptic process simulation is a true representation of your commercial filling. 2. The manufacturing operator can perform be documented if it is carried out within ~ Sci: 3. There are instances in which multiple interventions are carried out within the aseptic core and not documented. For example, on June 3 20 (b)( ) m~ m ml vial; lot (b)l,J) or { an empty vial from the conveyor just before the filling area. The operator went to the stoppering station and performed the "stopper sensor adjustment" intervention. 4. PR220186 was initiated on November 22, 2023, due to a finger dab of (b)(,() CFU of Micrococcus luteus during the filling activities. According to PR220186, the sample was taken after an intervention in the local filling room (6)<>. However, this intervention is not documented. Repeat Observation B. All integral filled units are not incubated during Media Fill Batch Records (MFBR) 1>)141 rnL; lot the filling portion of the media fill run. However, compromised the integrity of the vials that were manually rejected. C. The airflow pattern study [a.k.a. smoke studies] conducted in accordance with Report: (6)(,() titled "Operational Performance Qualification Report For (b) <> filling and Loading/Unloading Area (In Operation, With Interven 2021," is inadequate. Specifically, • Sufficient smoke is not generated to allow demonstration of flow • There are interventions where the smoke source is not positioned to allow sufficient smoke to enter the airflow over the operator/tools (e.g., forceps) during the intervention to visualize the impact this activity on the airflow. • There are interventions in which the video camera is placed behind the operator and the impact of the intervention on the airflow cannot be visualized. • There are interventions in which the video camera is too close to the operator's hands and the impact of the intervention on the airflow cannot be visualized. • There is no assurance that in critical areas point of use. The distance between the HEPA between the HEPA filters and the (f) if airflow evaluation for dynamic conditions. The study does not include filters to critical areas, including areas ~ air flow pattern and dynamic conditions. Additionally, there is no documented evidence of HEPA filters when evaluating (b) (conat 10ns. Repeat Observation D. Inadequate aseptic behavior pattern during commercial filling (b)(f) on the (b)(if) filling line. Specifically, • We observed two (2) manufacturing operators and one (1) microbiologist (Grade A area) during the filling process observed in the zone while the microbiologist was observed respectively. • We observed that two (2) operators at different times performed the intervention in the [<6)t('f>~ one. This intervention intervention. The equipment was never wiped after the intervention. • [<b)<">l 1inJ<6J<> repeatedly overlapped when operators exited the aseptic core. One (1) manufacturing operator touching adjust them
- Observation 5
Non‑compliant sterility testing
OBSERVATION 5 Each batch of product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Your QC laboratory does not follow the United States Pharmacopeia (USP) compendium for finished drug product sterility testing in that the product that causes turbidity 14 days incubation as per the USP. According to the USP chapter <71> "Sterility Test," if the material being tested renders the medium turbid so that the presence or absence of microbial growth cannot be determined by visual examination, 14 days after the beginning of incubation transfer portions (each not less than 1 ml) of the medium to fresh vessels of the same medium, and then incubate the original and transfer vessels for not less than 4 days. For example: A. [<6J(4) 1 . . t b) r(6) Ointment, (b)(4) lot 4 However, there is no assurance that product after subculture. Your QC laboratory completed the sterility test without any further testing. The reading of the test was observed on fl>l<1 B. (b)<4> Ointment~LJg, lot USA was tested for sterility and released after the
- Observation 6
Deficient endotoxin test procedures
OBSERVATION 6 Laboratory controls do not include the establishment procedures designed to assure that in process materials purity. A. Control procedures SOP #JHSM-MOA-000199, "Bacterial Endotoxin Test-LAL Gel-Clot Method" Rev. 16, effective 31 May 2023, SOP #JHSM-MOA-000194, "Bacterial Endotoxin Test Using the LAL Kinetic Turbidimetric System" Rev. 10, effective 09 Mar 2023 and Test Using the LAL Kinetic Chromogenic System" Rev. 12, effective 09 Mar 2023 do not state any instructions of how to mix our samples to be tested for endotoxin before they are tested for endotoxin. For example: 1. During the observation of the endotoxin testing (6f(4) on a (b)(:.) by Kinetic (b) (4) before a portion --------- 2. During the observation of the endotoxin testing method on 6/11/2024, a different analy (6)<> sample taken for the analysis. 3. During the observation of the endotoxin testing on 06/12/2024, the analyst did not 6>1 ('I) The product was transferred 8 206-EU-PRPQ-4206 performed in April 2022. Your QC laboratory did the (b)<4> during the -~b) <~ There is no way to measure/monitor the 4 b)<> In addition, there is no control procedure for
- Observation 7
Unvalidated disinfection methods
OBSERVATION 7 Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Your QC laboratory uses unvalidated method to disinfect product containers (6f("J) I Standard Operating procedures (SOP) number Method No. 999997, "Procedure for Sterility Testing" Rev. 41, effective 29 Nov. 2023, states that (6,{4) 4 Your lab logbook for disinfection (b)< > v ruJuct to be tested. In addition, the logbook does not indicate how long each product following are examples of products disinfected using 6fr4) EXAMPLE
- Observation 8
Inadequate environmental monitoring
OBSERVATION 8 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. A. Your Environmental Monitoring program is inadequate to assess the conditions environment and the ancillary clean areas. For example: 1. Your environmental monitoring program the floors, walls, and air (6}(.of) 2. Your firm does not investigate Environmental Monitoring alert and action level excursions that occurred in areas outside of your aseptic processing zones. You perform environmental monitoring in Grade C areas per JHSM-SOP-2003, Rev Monitorine-Sampling Plans and Conditions; however, when nlcrt Instruction, JHSM-SOP1396CNS02, Revision Requirements and Steps to Follow, states that you do not investigate an alert or action level excursion unless it occurred within an aseptic processing room. Furthermore, excursions where objectionable microorganisms are identified in Grade B and C areas are not investigated in processing rooms. 3. Your firm's environmental monitoring alert and action levels are based on recommended guidance data and not based on your facility's historical environmental data. Your action limit for active air sampling in Grade R. However, in the past 2 years, you have exceeded your active air excursion levels approximately 87 times; active air excursion levels have remained below ~ cfu/m3 in the Grade C area. B. Your procedures for personnel sampling and monitoring are deficient for personnel gowning that interact with the aseptic core areas. JHSM-SOP-115, 2023, procedure for "Good manufacturing practices and gowning procedure for aseptic zones" states that personnel use elbow or forearms to move the curtains to access the Grade A areas. However, your sampling plan for Gown and Gloves Monitoring, JHSM-SOP-2003INS17, Revision 15, Effective date Dec requires elbows to be monitored for personnel gowning. (6)(4)(b)(4) mg[:~ ml vial; lot (b)('f) operators were observed to be using their elbows to enter and exit the A area and use their elbows in consecutive motion to adjust the (6)<4> fitting line. C. Sampling plan- Glove and Gowns monitoring, JHSM-SOP-2003INS 17, Revision 15, Effective date Dec 18, 2023, is inadequate in that it does not define the types 4 Diagrams (b)( ) of Appendix {6 in your SOP list would require glove monitoring; however, the lists do not 4 for the (b)< l1,line (Room~6)<4) states major interventions during filling E~ 16f~) Information to establish types of interventions D. Your report for Environmental Monitoring loca # S-VARIOUS-EU-ST400, approved March 22, 2019, used locations for classified Grade A environments, including the filling line Room (b)(4) Grade A areas was found to be inadequate. 1. In your assessment, you defined l(fif~, --, critical points for filling and, (b) 4 your ~b)<>) learning line. Your assessment defining the critical operations, such as operator interventions, within each critical operators were evaluated to consider the current locations assessment is based on the review of movement smoke studies were found to be inadequate (See Observation 4). 2. Your firm established a minimum off 6f< located in the following areas: bf(<'I) ~6)(4) to capture the overall impact of the distance between each (b) operations to ensure accurate monitoring of NVP (b) c.ir line. The distance between each b) (4)
- Observation 9
Deficient complaint investigations
OBSERVATION 9 Written procedures describing the handling of quality control unit of any complaint involving specification is and a determination as to the need for an investigation. Your Quality Unit did not conduct a thorough evaluation or establish in a timely manner to address the complaints received. For example, from the period from June 1~?22 complaints related to the presence of (b)1:1 particles (b)<> o (b)<> [Injection!~~g/vial For all the cases, your Quality Unit concluded that 4 of the (b)< > ial, which would have been improper. I causing a coring defect. Therefore, no CAPA was 4 investigations, control samples were never b)<> 4 during product 6J<1 _pr is associate wit examination of the control samples has been carried out. Your Quality Unit carried out on the <1:>H > stopper yielded the expected result (e.g., size, dimensions) of the stoppers and not their functionality. (6J{'I) stopper during the qualification of your supplier.
- Observation 10
Incomplete batch records
OBSERVATION 10 Batch production and control records do not include complete information relating to the production and control of each batch. The aseptic core > To carry out the operation, must enter inside the aseptic core (Grade A) through the, (b) is Grade B. On June 03 June 2024, we observed the commercial filling ~b)(:iff7 Numerous operator interventions were observed in production, which were not documented in the manufacturing batch records. The following operator activities t6f(<l)7 For example, • We observed three (3) manufacturing operators within the aseptic core simultaneously. There is no maximum number of operators that can enter the Grade A. • There is no documentation in the batch records about the microbiological interventions performed during EM monitoring of the commercial filling. • An operator was observed removing an empty vial from the conveyor just before the filling area. Then, the same operator went to the stoppering station and performed the intervention. • The filling line was stopped and an operator was wipe sprayed with (bf(,l) 7 • The filling line was stopped, and an operator was observed wiping the (l(b)<> with a wipe sprayed with ~b)<> 7 • An operator was observed removing an empty vial from the conveyor • An operator was observed removing an empty vial from the • Operators were observed performing the intervention identified area approximately (8 times). During this intervention, the operator Additionally, your current practice is to not document routine corrective operator interventions that show a duration of less than (l>)<> in commercial batch records. 1
- Observation 11
Non‑sterile disinfectant use
OBSERVATION 11 Written procedures for cleaning and maintenance fail. Specifically, Your firm does not use sterile disinfectants to clean the aseptic processing and JHSM-SOP-1131, Preparation of Cleaning Solution and Disinfectant, Revision 10, effective, 14 June 2023 i< ~b)l4) (b)(4) For example: 1. A. (b)(4) lot1<bTT-'1'7~ (b)l~)'p KOOml(b)(4) filling area. (b){'f} 4 B. ot<6)14) ll(bff> 4 4 (b)<> filling room fo (b)<> : Sterile products. C. ~b)(.\J 6 1 lot1(b)(4) lt><~>7 filling area. 'i$t2t
- Observation 12
Inadequate equipment cleaning
OBSERVATION 12 Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. On June 10, 2024 we observed (b) line cleaning activities in Room filled (b)(if) products and sterile liquids for the US market. As part of manufacturing, an operator was cleaning the capping conveyor in the capping area with a (b)(.iJ) wipe containing a cleaning solution. Once the operator finished cleaning the conveyor, the cloth was observed with ~ According to Production Manager, the (b)<> pots are apparently conveyor that manufacturing operators do not have access to during manual cleaning. Specifically, it was explained that during cleaning the (6)(4) cleaning residue "to-come out of the conveyor during cleaning."
- Observation 13
Components not microbiologically tested
OBSERVATION 13 Each lot of a component that is liable to microbiological contamination that intended use is not subjected to microbiological tests before use. Your firm failed to test the purchased sterile components used to produce the sterile sterile (bff) ointment, for sterility before use received from the vendor. For example,
- Observation 14
Unqualified gram‑stain equipment
OBSERVATION 14 Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written. Your QC laboratory uses Previ-Color Gram, a gram staining automated machine from BioMerieux, Equipment #JH-U577 to perform gram stain test. Your QC laboratory failed to qualify this equipment before use, there was no Installation Qualification (IQ), Operational Qualification (OQ) or Performance Qualification (PQ) performed. This automated gram stain machine is in your identification laboratory and is used routine process of all organisms detected across your facility. There are 1,796 organisms identified in 2022, and 569 organisms identified in 2024 until now.
- Observation 15
Reserve samples not reviewed annually
OBSERVATION 15 Reserve samples from representative sample lots statistical procedures are not examined visually at least once a year. Your procedures for Annual Inspection of Reserve Samples, JHSM-SOP-1502INS03, Revision 07, effective date June 08 2022, are inadequate in that you do not perform a review of reserve during their shelf life. For example, on June 13, 2024 during a walkthrough ~6f(4) <dngtml, lot ~> Qualify On as part of your annual Inspection. The l placed on reserve o ~b) ) The shelf life of this product is In the retains warehouse it was determined that expiration date (6)1 ) was not reviewed by your 4 ot was manufactured on (b) < > and ~I} units were
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Comparison of Test Results to Specifications
Laboratory records are deficient in that they do not include a statement of the results of tests and how they compare to the established specifications.
Acceptance/Rejection Levels
The statistical quality control criteria fail to include appropriate acceptance levels and rejection levels.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy.
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality and purity.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
10 requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.
Inspection ending Nov 3, 2025OAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Feb 26, 2026. FDAgent holds no copy that FDA posted.
- Feb 22, 2026FDA-FOIA-2026-1848Form 483Records released
- Jan 12, 2026FDA-FOIA-2026-334Form 483· 1 of 2 sitesWithdrawn
Inspection ending Jun 14, 2024OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Jul 1, 2025FDA-FOIA-2025-8169Form 483 + EIRRecords released
- Sep 4, 2024FDA-FOIA-2024-7825Form 483Not Reasonably Described
Inspection ending Feb 28, 2023OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Aug 20, 2024FDA-FOIA-2024-7397Form 483Closed
- Jun 10, 2024FDA-FOIA-2024-5050Form 483Closed
Inspection ending Jun 1, 2018VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2022-8529Form 483 + EIRClosed
Inspection date not given
3 requests. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2023-6613EIRWithdrawn
- Oct 16, 2024FDA-FOIA-2024-9164Form 483Closed
- Oct 11, 2023FDA-FOIA-2023-8961EIRClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 10 inspections, with how many of them cited each.
- 21 CFR 211.113Control of microbiological contamination3 of 4
- 21 CFR 211.22Responsibilities of quality control unit2 of 4
- 21 CFR 211.160General requirements2 of 4
- 21 CFR 211.28Personnel responsibilities1 of 4
- 21 CFR 211.42Design and construction features1 of 4
- 21 CFR 211.67Equipment cleaning and maintenance1 of 4
- 21 CFR 211.100Written procedures; deviations1 of 4
- 21 CFR 211.165Testing and release for distribution1 of 4
Show all 12
- 21 CFR 211.170Reserve samples1 of 4
- 21 CFR 211.188Batch production and control records1 of 4
- 21 CFR 211.192Production record review1 of 4
- 21 CFR 211.194Laboratory records1 of 4
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Jubilant HollisterStier General PartnershipD-U-N-S 246762764
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3001623073 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3001623073. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.