FDA has 4 inspections on file for Playtex Manufacturing, Inc. in Sidney, Ohio (FEI 3000717960), from 2011 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant, Playtex Manufacturing Inc (D-U-N-S 049396471), has registered 1 other site.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2011–2025
- 0 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 4
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 2 requests, latest May 15, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Show 1 more citation
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Training , Education , Experience overall
Employees engaged in the processing of a drug product lack the training required to perform their assigned functions.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Inadequate number of personnel
The number of qualified personnel is inadequate to perform and supervise the manufacture, processing, packing, and holding of each drug product.
Components withheld from use pending release
Each lot of components is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Show 7 more citations
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, in-process materials, and drug products conform to appropriate standards of identity, strength, quality and purity.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.
Measured components for manufacturing
Components for drug product manufacturing are not weighed, measured, and subdivided as appropriate.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on May 15, 2026. Each one asked for a Form 483.
Inspection ending Apr 7, 2025VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- May 15, 2026FDA-FOIA-2026-5002Form 483· 1 of 5 sitesWithdrawn
- May 22, 2025FDA-FOIA-2025-4546Form 483· 1 of 4 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.192Production record review3 of 3
- 21 CFR 211.67Equipment cleaning and maintenance2 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 3
- 21 CFR 211.160General requirements2 of 3
- 21 CFR 211.198Complaint files2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.25Personnel qualifications1 of 3
Show all 13
- 21 CFR 211.63Equipment design, size, and location1 of 3
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 3
- 21 CFR 211.101Charge-in of components1 of 3
- 21 CFR 211.165Testing and release for distribution1 of 3
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Playtex Manufacturing IncD-U-N-S 049396471
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Playtex Manufacturing Inc (D-U-N-S 049396471) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Playtex Manufacturing IncOrmond Beach, Florida · FEI 10277355 inspections5latestJul 10, 2026OAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3000717960 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3000717960. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.