Whitney Labs LP
1095 N US Highway 1, Ormond Beach, Florida, United States
FEI 3000204465
FDA has 4 inspections on file for Whitney Labs LP in Ormond Beach, Florida (FEI 3000204465), from 2010 to 2015. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 21 citations from this inspection: 19 under 21 CFR Part 211, the manufacturing rules for finished drugs, and 2 under 21 CFR Part 314, the rules for new drug applications. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
19 regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 4, 2010–2015
- 4 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 4
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Unapproved and Misbranded Drugs21 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written in-process control procedures
Written procedures are not established and followed that describe the in-process controls and examinations to be conducted on appropriate samples of in-process materials of each batch.
Reserve samples identified, representative, stored
Reserve drug product samples are not representative of each lot or batch of drug product.
Distribution Record Requirements
Distribution records do not contain the lot or control number of drug product.
Individual inventory record
Records fail to include an individual inventory record of each component, reconciliation of the use of each component, and drug product container with sufficient information to allow determination of any associated batch or lot of drug product.
Results not used for expiration dates, storage cond.
Results of stability testing are not used in determining expiration dates.
Show 16 more citations
Calibration/Inspection/Checking not done
Routine calibration and checking of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.
Cleaning SOPs/instructions
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Training , Education , Experience overall
Employees engaged in the processing, packing, and holding of a drug product lack the education, training, and experience required to perform their assigned functions.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written, and followed.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit and reviewed and approved by the quality control unit.
Failure to meet specifications
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Items to cover on annual reviews
Written procedures are not established and followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Testing Each Component for Conformity with Specs
Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Failure to develop written procedures
Written procedures have not been developed for the surveillance, receipt, evaluation, and reporting to FDA of post marketing adverse drug experiences.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance17 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written in-process control procedures
Written procedures are not established and followed that describe the in-process controls and examinations to be conducted on appropriate samples of in-process materials of each batch.
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.
Distribution Record Requirements
Distribution records do not contain the lot or control number of drug product.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Show 12 more citations
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Reserve samples identified, representative, stored
Reserve drug product samples are not representative of each lot or batch of drug product.
Training , Education , Experience overall
Employees engaged in the processing, packing, and holding of a drug product lack the education, training, and experience required to perform their assigned functions.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit and reviewed and approved by the quality control unit.
Calibration/Inspection/Checking not done
Routine calibration, inspection, and checking of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of drug product containers and closures.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, and investigations conducted for each drug product.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written, and followed.
Calibration/Inspection/Checking not done
Routine calibration, inspection, and checking of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Show 7 more citations
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Reserve samples identified, representative, stored
Reserve drug product samples are not representative of each lot or batch of drug product.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Approval and review of procedures
Written procedures are not reviewed and approved by the quality control unit.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance15 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.
Reserve samples identified, representative, stored
Reserve drug product samples are not representative of each lot or batch of drug product.
Lack of quality control unit
There is no quality control unit.
Calibration/Inspection/Checking not done
Routine calibration, inspection, and checking of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Show 10 more citations
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written, and followed.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, and investigations conducted for each drug product.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Approval and review of procedures
Written procedures are not reviewed and approved by the quality control unit.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Regulations FDA cited here
The 23 sections of 21 CFR in FDA’s published citations for this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit4 of 4
- 21 CFR 211.67Equipment cleaning and maintenance4 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment4 of 4
- 21 CFR 211.100Written procedures; deviations4 of 4
- 21 CFR 211.125Labeling issuance4 of 4
- 21 CFR 211.170Reserve samples4 of 4
- 21 CFR 211.180General requirements4 of 4
- 21 CFR 211.25Personnel qualifications3 of 4
Show all 23
- 21 CFR 211.113Control of microbiological contamination3 of 4
- 21 CFR 211.166Stability testing3 of 4
- 21 CFR 211.80General requirements2 of 4
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 4
- 21 CFR 211.186Master production and control records2 of 4
- 21 CFR 211.188Batch production and control records2 of 4
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 211.196Distribution records2 of 4
- 21 CFR 211.198Complaint files2 of 4
- 21 CFR 211.28Personnel responsibilities1 of 4
- 21 CFR 211.142Warehousing procedures1 of 4
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 4
- 21 CFR 314.80Postmarketing reporting of adverse drug experiences1 of 4
- 21 CFR 314.81Other postmarketing reports1 of 4
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3000204465 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3000204465. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.