Viatris Pharmaceuticals LLC
Road #2 Km 58.2, Barceloneta, Puerto Rico, United States
FEI 2627208DUNS 829084545
FDA has 8 inspections on file for Viatris Pharmaceuticals LLC in Barceloneta, Puerto Rico (FEI 2627208), from 2010 to 2025. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Sep 23, 2011. 1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.
Eight regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant is Viatris Inc. (D-U-N-S 117542494).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 8, 2010–2025
- 1 OAI · 5 VAI · 2 NAI
- Inspections with 483 observations shown
- 5 of 8
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Following/documenting laboratory controls
Established standards are not followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Establishment of calibration procedures
Procedures describing the calibration of instruments, apparatus, gauges and recording devices are deficiently written or followed.
Calibration/Inspection/Checking not done
Routine calibration of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance16 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions and sampling and testing procedures.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed and documented at the time of performance.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
Valid stability test methods
The written stability program for drug products does not include reliable, meaningful, and specific test methods.
Show 11 more citations
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include assignment of responsibility and description in sufficient detail of methods, equipment and materials used.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Failure to meet specifications
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Laboratory equipment calibration records
Laboratory records do not include complete records of the periodic calibration of laboratory instruments.
Cleaning/maintenance records not kept
Records are not kept for the maintenance and inspection of equipment.
Sample identification and other information
Laboratory records do not include the quantity of the sample.
Reserve samples identified, representative, stored
Reserve drug product samples are not appropriately identified.
input/output verification
Input to and output from the computer, related systems of formulas, and records or data are not checked for accuracy.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Data secured in course of each test
Laboratory records do not include a complete record of all data secured in the course of each test, including all graphs from laboratory instrumentation, properly identified to show the lot tested and drug product tested.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not followed.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 4 more citations
Acceptance of in-process materials
Determinations of conformance to appropriate written specifications for acceptance are not made for in-process materials.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions and special notations.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that in-process materials conform to appropriate standards of identity, strength, quality and purity.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Determination not to conduct investigation of complaint
The written record did not include the reason an investigation was found not to be necessary when an investigation into unexplained discrepancies was not conducted.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Regulations FDA cited here
The 15 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 8 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements4 of 5
- 21 CFR 211.67Equipment cleaning and maintenance3 of 5
- 21 CFR 211.192Production record review3 of 5
- 21 CFR 211.198Complaint files3 of 5
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 5
- 21 CFR 211.186Master production and control records2 of 5
- 21 CFR 211.194Laboratory records2 of 5
- 21 CFR 211.22Responsibilities of quality control unit1 of 5
Show all 15
- 21 CFR 211.80General requirements1 of 5
- 21 CFR 211.100Written procedures; deviations1 of 5
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 5
- 21 CFR 211.113Control of microbiological contamination1 of 5
- 21 CFR 211.166Stability testing1 of 5
- 21 CFR 211.170Reserve samples1 of 5
- 21 CFR 314.81Other postmarketing reports1 of 5
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 2627208, one row per refused product line.
1 refusal on 2024-02-14 · charged UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2024-02-14
DOXAZOSIN MESYLATE (ANTI-HYPERTENSIVE - PART II)62ODY27
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-4692799-0/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Viatris Inc.D-U-N-S 117542494
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as Viatris Pharmaceuticals LLC
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Viatris Pharmaceuticals LLCFEI 2623619Vega Baja, Puerto Rico, United States
Last inspected 2026-05-18VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2627208 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2627208. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.