Hercon Pharmaceuticals, LLC
101 Aberdeen Rd, Emigsville, Pennsylvania, United States
FEI 2522638
FDA has 5 inspections on file for Hercon Pharmaceuticals, LLC in Emigsville, Pennsylvania (FEI 2522638), from 2009 to 2019. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2009–2019
- 0 OAI · 4 VAI · 1 NAI
- Inspections with 483 observations shown
- 4 of 5
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Instruments, apparatus, et. al. not meeting specs
The use of instruments not meeting established specifications was observed.
Calibration/Inspection/Checking not done
Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Lab controls established, including changes
The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred.
Calibration/Inspection/Checking not done
Routine calibration, inspection, and checking of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions.
Show 8 more citations
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used.
Extent of discrepancy, failure investigations
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
Written complaint record to be maintained at facility
A written record of each complaint is not maintained in a file designated for drug product complaints at the facility where the drug product was manufactured, processed or packed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Lab controls established, including changes
The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Equipment for Environmental Control
Equipment for adequate control over air pressure, micro-organisms, dust, humidity, and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Approval and review of procedures
Written procedures are not drafted, reviewed and approved by the appropriate organizational units and reviewed and approved by the quality control unit.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements3 of 4
- 21 CFR 211.192Production record review3 of 4
- 21 CFR 211.22Responsibilities of quality control unit2 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 4
- 21 CFR 211.100Written procedures; deviations2 of 4
- 21 CFR 211.198Complaint files2 of 4
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 4
- 21 CFR 211.67Equipment cleaning and maintenance1 of 4
Show all 12
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 4
- 21 CFR 211.180General requirements1 of 4
- 21 CFR 211.186Master production and control records1 of 4
- 21 CFR 211.188Batch production and control records1 of 4
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2522638 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2522638. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.