Vitaminerals, Inc.
1815 Flower St, Glendale, California, United States
FEI 2010340
FDA has 4 inspections on file for Vitaminerals, Inc. in Glendale, California (FEI 2010340), from 2009 to 2016. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.160(b).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2009–2016
- 0 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 4
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Acceptance of drug products
Determinations of conformance to appropriate written specifications for acceptance are not made and deficient for drug products.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Approval and review of procedures
Written procedures are not drafted, reviewed and approved by the appropriate organizational units.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Show 1 more citation
Records not made readily available to FDA
Records associated with drug product production and control and within the retention period for such records, were not made readily available for authorized inspection.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Identification of Equipment and Lines
The batch production and control records are deficient in that they do not include the identity of major equipment used.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 2 more citations
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, and test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written records kept in individual logs
Written records of major equipment maintenance and use are not included in individual equipment logs.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, and test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements3 of 3
- 21 CFR 211.188Batch production and control records2 of 3
- 21 CFR 211.58Maintenance1 of 3
- 21 CFR 211.63Equipment design, size, and location1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
- 21 CFR 211.142Warehousing procedures1 of 3
- 21 CFR 211.165Testing and release for distribution1 of 3
- 21 CFR 211.170Reserve samples1 of 3
Show all 12
- 21 CFR 211.180General requirements1 of 3
- 21 CFR 211.182Equipment cleaning and use log1 of 3
- 21 CFR 211.192Production record review1 of 3
- 21 CFR 211.194Laboratory records1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2010340 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2010340. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.