Virbac Corporation
13001 Saint Charles Rock Rd, Bridgeton, Missouri, United States
FEI 1944921DUNS 829166276
FDA has 10 inspections on file for Virbac Corporation in Bridgeton, Missouri (FEI 1944921), from 2009 to 2026. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Jan 22, 2026. FDA has issued 2 warning letters under this FEI, the latest on (CVM). No court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.110(a), 21 CFR 211.165(f) and 21 CFR 211.192.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis, relabeling and repacking, through Dec 31, 2026. Its registrant is Virbac Corporation (D-U-N-S 131568396).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 10, 2009–2026
- 2 OAI · 5 VAI · 3 NAI
- Inspections with 483 observations shown
- 3 of 10
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest Mar 20, 2026
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upVeterinary · Pre-Approval Eval. of Animal Drugs and Food AdditivesNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food AdditivesCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices26 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
Mfg and control changes not requiring a supplemental app.
An annual report did not include a full description of the manufacturing and control changes not requiring a supplemental application, listed by date in the order in which they were implemented.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit and reviewed and approved by the quality control unit.
Complaint Investigation/Follow-Up Findings
Complaint records are deficient in that they do not include the findings of the investigation and follow-up.
Written warehousing procedures established/followed
Procedures describing the warehousing of drug products are not established and followed.
Show 21 more citations
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Lack of quality control unit
There is no quality control unit.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Quality Control Review
Complaint procedures are deficient in that they do not include provisions that allow for the review and determination of an investigation by the quality control unit.
Acceptance/Rejection Levels
The statistical quality control criteria fail to include appropriate acceptance levels and rejection levels.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Representative samples after completion
Samples of representative units were not collected and visually examined for correct labeling at the completion of finishing operations.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing, and packaging of the drug product.
Record maintenance 1 year (except exempt OTC)
All records of production, control, distribution, components, drug product containers, closures, and labeling associated with a batch of drug product are not maintained at least one (1) year after the expiration date.
Late submission of 15-day report
Not all adverse drug experiences that are both serious and unexpected have been reported to FDA within 15 calendar days of initial receipt of the information.
Calibration/Inspection/Checking not done
Routine calibration, inspection, and checking of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Timely submission
An annual report was not submitted each year and within 60 days of the anniversary date of U.S. approval of the application to the FDA division responsible for reviewing the application.
Quarantine Storage of Components
Incoming drug product containers and closures are not stored under quarantine until they have been tested or examined, as appropriate, and released.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
In-process samples representative, identified properly
Samples taken of in-process materials for determination of conformance to specifications are not representative.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Testing Each Component for Conformity with Specs
Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Failure to meet specifications
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug product containers, closures, labeling, and drug products conform to appropriate standards of identity, strength, quality and purity.
Examinations documented
The results of the examination of the packaged and labeled products were not documented in the batch production or control records.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Inadequate number of personnel
The number of qualified personnel is inadequate to the manufacture of each drug product.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Rejecting When Specifications Not Met
Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Mar 20, 2026. Each one asked for a Form 483.
Inspection ending Jan 22, 2026OAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 13, 2026. FDAgent holds no copy that FDA posted.
- Mar 20, 2026FDA-FOIA-2026-2780Form 483· 1 of 5 sitesRecords released
Inspection ending Jul 28, 2023VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 22, 2025FDA-FOIA-2025-9068Form 483Closed
- Dec 11, 2023FDA-FOIA-2023-10992Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 18 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 10 inspections, with how many of them cited each.
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 3
- 21 CFR 211.134Drug product inspection2 of 3
- 21 CFR 211.160General requirements2 of 3
- 21 CFR 211.165Testing and release for distribution2 of 3
- 21 CFR 211.192Production record review2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.25Personnel qualifications1 of 3
Show all 18
- 21 CFR 211.67Equipment cleaning and maintenance1 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.82Receipt and storage of untested components, drug product containers, and closures1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
- 21 CFR 211.103Calculation of yield1 of 3
- 21 CFR 211.142Warehousing procedures1 of 3
- 21 CFR 211.180General requirements1 of 3
- 21 CFR 211.198Complaint files1 of 3
- 21 CFR 314.80Postmarketing reporting of adverse drug experiences1 of 3
- 21 CFR 314.81Other postmarketing reports1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCVM · VeterinaryFDA record
- Warning letterFormal notice of significant violationsCVM · VeterinaryFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, relabeling, repacking
- Registration runs through
- Dec 31, 2026
- Registrant
- Virbac CorporationD-U-N-S 131568396
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1944921 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1944921. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.