Consolidated Chemical, Inc
3224 S Kingshighway Blvd, Saint Louis, Missouri, United States
FEI 1940465
FDA has 6 inspections on file for Consolidated Chemical, Inc in Saint Louis, Missouri (FEI 1940465), from 2009 to 2022. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. One FOIA request has asked FDA for this inspection's 483.
FDA's compliance record also lists one other action under this FEI: Injunction, . No warning letter or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.100(a) and 21 CFR 211.113(a).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 6, 2009–2022
- 4 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 6
- 4 posted 483s not matched to an inspection
- Requested under FOIA
- 1 request, latest Apr 4, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected.
Returned drug products with doubt cast as to safety et. al.
Returned drug products held, stored or shipped before or during their return under conditions which cast doubt on their safety, identity, strength, quality or purity are not subjected to examination, testing or other investigation to prove the drug products do meet all the necessary parameters.
Written Procedures Not Followed
Written procedures are not followed for the storage and handling of components.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that conform to appropriate standards of identity, strength, quality and purity.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance15 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not justified.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to approve and reject all components, drug product containers, closures, in process materials, packaging material, labeling, and drug products.
Show 10 more citations
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written, and followed.
Component addition checked by 2nd person
Each component is not added to a batch by one person and verified by a second person.
Reprocessing procedures not written or followed
Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not followed.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Establish reliability of supplier's C of A
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Calibration/Inspection/Checking not done
Routine calibration, inspection, and checking of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.
Review of representative number of batches
Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Test methods
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Apr 4, 2025. It asked for a Form 483.
Inspection ending Aug 2, 2022OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Apr 4, 2025FDA-FOIA-2025-3041Form 483· 1 of 2 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 18 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.100Written procedures; deviations2 of 3
- 21 CFR 211.113Control of microbiological contamination2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.58Maintenance1 of 3
- 21 CFR 211.67Equipment cleaning and maintenance1 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 3
Show all 18
- 21 CFR 211.101Charge-in of components1 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.115Reprocessing1 of 3
- 21 CFR 211.142Warehousing procedures1 of 3
- 21 CFR 211.160General requirements1 of 3
- 21 CFR 211.165Testing and release for distribution1 of 3
- 21 CFR 211.180General requirements1 of 3
- 21 CFR 211.188Batch production and control records1 of 3
- 21 CFR 211.192Production record review1 of 3
- 21 CFR 211.204Returned drug products1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- InjunctionCDER · DrugsFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1940465 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1940465. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.